CISCOSB-RLINVENTORYENT-MIB DEFINITIONS ::= BEGIN

IMPORTS
    switch001                                            FROM CISCOSB-MIB
    Unsigned32, OBJECT-TYPE                              FROM SNMPv2-SMI
    DisplayString                                        FROM RFC1213-MIB;


UnitIfindexType ::= TEXTUAL-CONVENTION
    STATUS                 current
    DESCRIPTION          "Unit or ifindex type."
    SYNTAX  INTEGER {
        unit(0),
        ifindex(1)
}

    rlInventoryEntTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RlInventoryEntEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION        "A table that contains INVENTORY entities in the system."
    ::= { switch001 217 }


   rlInventoryEntEntry OBJECT-TYPE
    SYNTAX              RlInventoryEntEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION        "An entry (conceptual row) in the  rlInventoryEnvTable."
    INDEX  { rlInventoryEntUnitOrIfindex ,rlInventoryEntUnitIfindexID }
    ::= { rlInventoryEntTable 1 }

    RlInventoryEntEntry::= SEQUENCE {
    rlInventoryEntUnitOrIfindex             UnitIfindexType,
    rlInventoryEntUnitIfindexID             Unsigned32,
    rlInventoryEntVendorID                  DisplayString,
    rlInventoryEntPID                       DisplayString,
    rlInventoryEntName                      DisplayString,
    rlInventoryEntDescription               DisplayString,
    rlInventoryEntSerialNumber              DisplayString,
    rlInventoryEntUnitNum                   Unsigned32
    }

    rlInventoryEntUnitOrIfindex OBJECT-TYPE
    SYNTAX              UnitIfindexType
    MAX-ACCESS          read-only
        STATUS              current
    DESCRIPTION        "this field will be equal to zero if this is a unit else 1 if this is a port."
    ::= { rlInventoryEntEntry 1 }


    rlInventoryEntUnitIfindexID OBJECT-TYPE
    SYNTAX             Unsigned32
    MAX-ACCESS        read-only
    STATUS              current
    DESCRIPTION        "if rlInventoryEntUnitOrIfindex = 0 this field contain the unit number else if  rlInventoryEntUnitOrIfindex = 1
This field contain the if_index number."
    ::= { rlInventoryEntEntry 2 }


    rlInventoryEntVendorID OBJECT-TYPE
    SYNTAX              DisplayString
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION        "Vendor identification"
    ::= { rlInventoryEntEntry 3 }

    rlInventoryEntPID OBJECT-TYPE
    SYNTAX              DisplayString
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION         "Physical identification"
    ::= { rlInventoryEntEntry 4}

    rlInventoryEntName OBJECT-TYPE
    SYNTAX              DisplayString
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION         "Unit number of interface name"
    ::= { rlInventoryEntEntry 5 }

    rlInventoryEntDescription OBJECT-TYPE
    SYNTAX              DisplayString
    MAX-ACCESS           read-only
        STATUS              current
    DESCRIPTION             "Description of the entity"
    ::= { rlInventoryEntEntry 6}

   rlInventoryEntSerialNumber OBJECT-TYPE
    SYNTAX              DisplayString
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION        "The serial number of the interface or unit."
    ::= { rlInventoryEntEntry 7 }

   rlInventoryEntUnitNum OBJECT-TYPE
    SYNTAX              Unsigned32
    MAX-ACCESS        	read-only
    STATUS              current
    DESCRIPTION        "if rlInventoryEntUnitOrIfindex = 1 this field contain the unit number that associated to this port"
    ::= { rlInventoryEntEntry 8 }


END