-- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved.
-- 
-- Description: Huawei Entity extent MIB File for environment
-- Reference:   
-- Version:     V1.10
-- History:
-- 
--  2005-04-16  V1.10   Cui Kemao(20339), Added replaceable unit Information
--  2003-07-28  V1.00   Chen baojiang & Ma ye, Initial Version
-- =================================================================

    HUAWEI-ENTITY-EXTENT-MIB DEFINITIONS ::= BEGIN
 
        IMPORTS
            entPhysicalIndex            
                FROM ENTITY-MIB            
            hwDatacomm            
                FROM HUAWEI-MIB            
            SnmpAdminString            
                FROM SNMP-FRAMEWORK-MIB            
            OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP            
                FROM SNMPv2-CONF            
            Integer32, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE            
                FROM SNMPv2-SMI            
            DateAndTime, TEXTUAL-CONVENTION,  RowStatus, DisplayString           
                FROM SNMPv2-TC
            EnabledStatus
                FROM P-BRIDGE-MIB 
            InterfaceIndex
                FROM IF-MIB;    
    
        hwEntityExtentMIB MODULE-IDENTITY 
            LAST-UPDATED "200606290000Z"        -- June 29, 2006 at 00:00 GMT
            ORGANIZATION 
                "Huawei Technologies co.,Ltd."
            CONTACT-INFO 
                " R&D BeiJing, Huawei Technologies co.,Ltd.
                Huawei Bld.,NO.3 Xinxi Rd., 
                Shang-Di Information Industry Base,
                Hai-Dian District Beijing P.R. China
            Zip:100085 
            Http://www.huawei.com                                       
            E-mail:support@huawei.com "
        DESCRIPTION 
            "The private mib file includes the general extent 
            information of the device."
        ::= { hwDatacomm 31 }

    --
    -- Textual conventions
    --
    HwAdminState ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION 
            " Represents the various possible administrative states.
            A value of locked means the resource is administratively
            prohibited from use. A value of shuttingDown means that
            usage is administratively limited to current instances of
            use. A value of unlocked means the resource is not
            administratively prohibited from use. A value of up means
            that the port is not administratively shut down and a value 
            of down is the oppsite. A value of loopback here means the
            port is working in the loopback local mode. When a port is
            both shut down and looped back, we user the vale of down."
        REFERENCE 
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX INTEGER
            {
            notSupported(1),
            locked(2),
            shuttingDown(3),
            unlocked(4),
            up(11),
            down(12),
            loopback(13)
            }
        
    HwOperState ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION 
            " Represents the possible values of operational states.
            A value of disabled means the resource is totally
            inoperable. A value of enabled means the resource
            is partially or fully operable. The values up(11),down(12) and
            connect(13) is used only for NE5000E BTB or it's extended system.
            A value of protocolUp means the port is available in the protocol
            lay or has already prepared for transmitting or receiving data.
            A value of linkUp means the port is only available in the physical
            lay. A value of linkDown means the port is not available physically."
        REFERENCE 
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX INTEGER
            {
            notSupported(1),
            disabled(2),
            enabled(3),
            offline(4),
            up(11),
            down(12),
            connect(13),
            protocolUp(15),
            linkUp(16),
            linkDown(17)    
            }
     
  HWLevelState ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION 
            "The normal state of input line ."
        SYNTAX INTEGER
            {
            lowLevel(1),
            highLevel(2)
                }
            
        HwStandbyStatus ::= TEXTUAL-CONVENTION
            STATUS current
            DESCRIPTION 
                " Represents the possible values of standby status.
                
            A value of hotStandby means the resource is not providing
            service, but is will be immediately able to take over the
            role of the resource to be backed-up, without the need for
            initialization activity, and will contain the same
            information as the resource to be backed up. A value of
            coldStandy means that the resource is to back-up another
            resource, but will not be immediately able to take over
            the role of a resource to be backed up, and will require
            some initialization activity. A value of providingService
            means the resource is providing service."
        REFERENCE 
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX INTEGER
            {
                notSupported(1),
                hotStandby(2),
                coldStandby(3),
                providingService(4)
                }
            
--     Not defined in X.731
        HwAlarmStatus ::= TEXTUAL-CONVENTION
            STATUS current
            DESCRIPTION 
                "Represents the possible values of alarm status.
                When no bits of this attribute are set, then none of the
                status conditions described below are present. When the
                value of under repair is set, the resource is currently
                being repaired.
                
                When the value of critical is set, one or more critical
                alarms are active against the resource. When the value of
                major is set, one or more major alarms are active against
                the resource. When the value of minor is set, one or more
                minor alarms are active against the resource. When the
                value of warning is set, one or more warning alarms are
                active against the resource. When the value of
                indeterminate is set, one or more  alarms of indeterminate
                severity are active against the resource.
                
                When the value of alarm outstanding is set, one or more
                alarms is active against the resource. The fault may or may
                not be disabling. "
            REFERENCE 
                "ITU Recommendation X.731, 'Information Technology - Open
                Systems Interconnection - System Management: State
                Management Function', 1992"
            SYNTAX BITS
                {
                notSupported(0),
                underRepair(1),
                critical(2),
                major(3),
                minor(4),
                alarmOutstanding(5),
                warning(6),
                indeterminate(7)
                }
            
    
--
-- Node definitions
--
    
        hwEntityExtObjects OBJECT IDENTIFIER ::= { hwEntityExtentMIB 1 }
        
--     MIB contains four groups      
-- 
        hwEntityState OBJECT IDENTIFIER ::= { hwEntityExtObjects 1 }
        
        hwEntityStateTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwEntityStateEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table contains one row per physical entity, There is
                always at least one row for an 'overall' physical entity.
                The information in each row may be not include all the object
                in this table, because of the entity need not some of the 
                information here. "
            ::= { hwEntityState 1 }
        
        hwEntityStateEntry OBJECT-TYPE
            SYNTAX HwEntityStateEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Information about a particular physical entity.
            Each entry provides objects (entPhysicalDescr,
            entPhysicalVendorType, and entPhysicalClass) to help an NMS
            identify and characterize the entry, and objects
            (entPhysicalContainedIn and entPhysicalParentRelPos) to help
            an NMS relate the particular entry to other entries in this
            table."
        INDEX { entPhysicalIndex }
        ::= { hwEntityStateTable 1 }
    
    HwEntityStateEntry ::=
        SEQUENCE { 
            hwEntityAdminStatus
                HwAdminState,
            hwEntityOperStatus
                HwOperState,
            hwEntityStandbyStatus
                HwStandbyStatus,
            hwEntityAlarmLight
                HwAlarmStatus,
            hwEntityCpuUsage
                INTEGER,
            hwEntityCpuUsageThreshold
                    INTEGER,
                hwEntityMemUsage
                    INTEGER,
                hwEntityMemUsageThreshold
                    INTEGER,
                hwEntityMemSize
                    Integer32,
                hwEntityUpTime
                    Integer32,
                hwEntityTemperature
                    Integer32,
                hwEntityTemperatureThreshold
                    Integer32,
                hwEntityVoltage
                    Integer32,
                hwEntityVoltageLowThreshold
                    Integer32,
                hwEntityVoltageHighThreshold
                    Integer32,        
                hwEntityTemperatureLowThreshold
                    Integer32,                    
                hwEntityOpticalPower    
                    Integer32,
                hwEntityCurrent
                    Integer32,
                hwEntityMemSizeMega
                    Integer32, 
                hwEntityPortType 
                    INTEGER, 
                hwEntityDuplex
                    INTEGER,
                hwEntityOpticalPowerRx    
                    Integer32,
                hwEntityCpuUsageLowThreshold
                    Integer32

             }

        hwEntityAdminStatus OBJECT-TYPE
            SYNTAX HwAdminState
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The administrative state for this object, and it is possible to set
                the state when needed. "
            ::= { hwEntityStateEntry 1 }
        
        hwEntityOperStatus OBJECT-TYPE
            SYNTAX HwOperState
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The operational state for this object. "
            ::= { hwEntityStateEntry 2 }
        
        hwEntityStandbyStatus OBJECT-TYPE
            SYNTAX HwStandbyStatus
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " Some entity in a device can support standby mode,
                This object is used for monitoring standby status. "
            ::= { hwEntityStateEntry 3 }
        
        hwEntityAlarmLight OBJECT-TYPE
            SYNTAX HwAlarmStatus
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The alarm status for this entity. It does not include
                the severity of alarms raised on child components. On 
                the condition, there are a alarm light on the entity, 
                the object should have the same status with it."
            ::= { hwEntityStateEntry 4 }
        
        hwEntityCpuUsage OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The CPU usage for this entity. Generally, the CPU usage 
                will calculate the overall CPU usage on the entity, and it 
                is not sensible with the number of CPU on the entity. "
            ::= { hwEntityStateEntry 5 }
        
        hwEntityCpuUsageThreshold OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The threshold for the CPU usage. When the CPU usage exceed
                the threshold, a notification will be sent. "
            ::= { hwEntityStateEntry 6 }
        
        hwEntityMemUsage OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The memory usage for the entity. This object point out how
                many percent of memory has been used. "
            ::= { hwEntityStateEntry 7 }
        
        hwEntityMemUsageThreshold OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The threshold for the Memory usage, When the memory usage 
                exceed the threshold, a notification will be sent. "
            ::= { hwEntityStateEntry 8 }
        
        hwEntityMemSize OBJECT-TYPE
            SYNTAX Integer32
            UNITS "bytes"
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The size of memory for the entity. "
            ::= { hwEntityStateEntry 9 }
        
        hwEntityUpTime OBJECT-TYPE
            SYNTAX Integer32
            UNITS "seconds"
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The up time for the entity. The mean of up time is
                when the entity is up, and the value of the object 
                will add one per seconds while the entity running. "
            ::= { hwEntityStateEntry 10 }
        
        hwEntityTemperature OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The temperature for the entity. "
            ::= { hwEntityStateEntry 11 }
        
        hwEntityTemperatureThreshold OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The threshold for the temperature. When the temperature
                exceed the threshold, a notification will be sent. "
            ::= { hwEntityStateEntry 12 }
        
        hwEntityVoltage OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The voltage for the entity. "
            ::= { hwEntityStateEntry 13 }
        
        hwEntityVoltageLowThreshold OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The low-threshold for the voltage. Generally, we have two 
                threshold for the voltage, one is low-threshold, and the other
                is high-threshold. the normal status of voltage should be
                greater than the low-threshold, and lower than the high-threshold.
                When the voltage low than the low-threshold, a notification
                will be sent. "
            ::= { hwEntityStateEntry 14 }
        
        hwEntityVoltageHighThreshold OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The low-threshold for the voltage. Generally, we have two 
                threshold for the voltage, one is low-threshold, and the other
                is high-threshold. the normal status of voltage should be
                greater than the low-threshold, and lower than the high-threshold.
                When the voltage greater than the high-threshold, a notification
                will be sent. "
            ::= { hwEntityStateEntry 15 }
            
        hwEntityTemperatureLowThreshold OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The low-threshold of temperature. If the device temperature is 
                 lower than the threshold, an alarm is raised.
                "
            ::= { hwEntityStateEntry 16 }
            
        hwEntityOpticalPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The optical power of the optical module. Unit: uW"
            ::= { hwEntityStateEntry 17 }      
          

        hwEntityCurrent OBJECT-TYPE
            SYNTAX Integer32
            UNITS "A"
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The current for the entity. "
            ::= { hwEntityStateEntry 18 }
        
        hwEntityMemSizeMega OBJECT-TYPE
            SYNTAX Integer32
            UNITS "M bytes"
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " The size of SDRAM(Synchronous Dynamic Random Access Memory) memory for the entity. Unit: M bytes"
            ::= { hwEntityStateEntry 19 }            
        hwEntityPortType OBJECT-TYPE
            SYNTAX INTEGER { 
                    notSupported(1),
                    copper(2),
                    fiber100(3),
                    fiber1000(4)
                   }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " Indicates the type of the Ethernet interface: an optical interface or an electrical interface. "
            ::= { hwEntityStateEntry 20 }
        hwEntityDuplex OBJECT-TYPE
            SYNTAX INTEGER {
                    notSupported(1), 
                    full(2),
                    half(3)
                   }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                " Indicates the duplex mode of the Ethernet interface. An electrical Ethernet interface can 
                work in half-duplex mode or full-duplex mode. An optical Ethernet can work only in full-duplex mode. "
            ::= { hwEntityStateEntry 21 }

        hwEntityOpticalPowerRx OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The optical power(Rx) of the optical module. Unit: uW"   
            ::= { hwEntityStateEntry 22 }
        hwEntityCpuUsageLowThreshold OBJECT-TYPE
            SYNTAX Integer32 (0..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                " The threshold for the CPU usage. When the CPU usage exceed
                the threshold, a notification will be sent. "
            ::= { hwEntityStateEntry 23 }
                  
        hwRUModuleInfoTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwRUModuleInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table contains one row per replaceable unit physical entity.
                The row with the field 'entPhysicalIsFRU' sets to 'true' in 
                table 'entPhysicalTable' will be mapped to one row in this 
                table."
            ::= { hwEntityState 2 }
        
        hwRUModuleInfoEntry OBJECT-TYPE
            SYNTAX HwRUModuleInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Information about a replaceable unit physical entity.
            Each entry provides objects of a replaceable unit to help 
            an NMS identify and characterize the entry in this table.
            "
        INDEX { entPhysicalIndex }
        ::= { hwRUModuleInfoTable 1 }
    
    HwRUModuleInfoEntry ::=
        SEQUENCE { 
            hwEntityBomId
                SnmpAdminString,
            hwEntityBomEnDesc
                    SnmpAdminString,
                hwEntityBomLocalDesc
                    SnmpAdminString,
                hwEntityManufacturedDate
                    DateAndTime,
                hwEntityManufactureCode
                    Integer32,
                hwEntityCLEICode
                    SnmpAdminString,
                hwEntityUpdateLog
                    SnmpAdminString,
                hwEntityArchivesInfoVersion
                    SnmpAdminString,
                hwEntityOpenBomId
                    SnmpAdminString,
                hwEntityIssueNum
                    SnmpAdminString,
                hwEntityBoardType
                    SnmpAdminString
             }

        hwEntityBomId OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The identity of the Bill of Material about this replaceable 
                unit which coded by vendor. This node is mapping to 'ITEM' 
                in the information file.
                "
            ::= { hwRUModuleInfoEntry 1 }
        
        hwEntityBomEnDesc OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The English description of the Bill of Material about this 
                replaceable unit.
                "
            ::= { hwRUModuleInfoEntry 2 }
        
        hwEntityBomLocalDesc OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "The local description of the Bill of Material about this 
                replaceable unit.
                "
            ::= { hwRUModuleInfoEntry 3 }
        
        hwEntityManufacturedDate OBJECT-TYPE
            SYNTAX DateAndTime
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The date when this physical entity is Manufactured.
                "
            ::= { hwRUModuleInfoEntry 4 }
        
        hwEntityManufactureCode OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "The code of the place where this physical entity is Manufactured.
                "
            ::= { hwRUModuleInfoEntry 5 }
        
        hwEntityCLEICode OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The string code of CLEI which was granted by America.
                "
            ::= { hwRUModuleInfoEntry 6 }
        
        hwEntityUpdateLog OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "The maintenance log of this replaceable unit.
                "
            ::= { hwRUModuleInfoEntry 7 }
        
        hwEntityArchivesInfoVersion OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The Version of Archives Information.
                "
            ::= { hwRUModuleInfoEntry 8 }
        
        hwEntityOpenBomId OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The BomId for distribution. It is different from hwEntityBomId."
            ::= { hwRUModuleInfoEntry 9 }
        
        hwEntityIssueNum OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The issue number for hardware change."
            ::= { hwRUModuleInfoEntry 10 }
        
        hwEntityBoardType OBJECT-TYPE
            SYNTAX SnmpAdminString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The type code for entity."
            ::= { hwRUModuleInfoEntry 11 }
        hwOpticalModuleInfoTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwOpticalModuleInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Table of optical module properties."
            ::= { hwEntityState 3 }
        
        hwOpticalModuleInfoEntry OBJECT-TYPE
            SYNTAX HwOpticalModuleInfoEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An entry in the table of optical module properties for each optical module."
        INDEX { entPhysicalIndex }
        ::= { hwOpticalModuleInfoTable 1 }
    
        HwOpticalModuleInfoEntry ::=
            SEQUENCE { 
                hwEntityOpticalMode
                    INTEGER,
                hwEntityOpticalWaveLength
                    Integer32,
                hwEntityOpticalTransDistance
                    Integer32,
                hwEntityOpticalVendorSn
                    SnmpAdminString,
                hwEntityOpticalTemperature
                    Integer32,
                hwEntityOpticalVoltage
                    Integer32,
                hwEntityOpticalBiasCurrent
                    Integer32,
                hwEntityOpticalRxPower
                    Integer32,
                hwEntityOpticalTxPower
                    Integer32                                                                                
            }   
                  
        hwEntityOpticalMode OBJECT-TYPE
            SYNTAX INTEGER
            {
                notSupported(1),
                singleMode(2),
                multiMode5(3),
                multiMode6(4),
                noValue(5)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The mode of the optical module."
            DEFVAL { notSupported }
            ::= { hwOpticalModuleInfoEntry 1 }

        hwEntityOpticalWaveLength OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The wave length of the optical module. Unit: nm."
            ::= { hwOpticalModuleInfoEntry 2 }

        hwEntityOpticalTransDistance OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The max transmission distance of the optical module. Unit: m."
            ::= { hwOpticalModuleInfoEntry 3 }

        hwEntityOpticalVendorSn   OBJECT-TYPE
            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The vendor serial number (vendor SN) of the optical module. Length: 16 bytes."
        ::= { hwOpticalModuleInfoEntry 4 }
                         
        hwEntityOpticalTemperature   OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The current temperature of the optical module. Unit: ."
        ::= { hwOpticalModuleInfoEntry 5 }        
        
        hwEntityOpticalVoltage   OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The current voltage of the optical module. Unit: mV."
        ::= { hwOpticalModuleInfoEntry 6 }
        
        hwEntityOpticalBiasCurrent   OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The bias current of the optical module. Unit: mA."
        ::= { hwOpticalModuleInfoEntry 7 }        
        
        hwEntityOpticalRxPower   OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The receive power of the optical module. Unit: uW."
        ::= { hwOpticalModuleInfoEntry 8 }
        
        hwEntityOpticalTxPower   OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                "The transmit power of the optical module. Unit: uW."
        ::= { hwOpticalModuleInfoEntry 9 }                               
                    
        hwMonitorInputTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwMonitorInputEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table contains one row per replaceable unit physical entity.
                This table is used to set the status of monitor port."
            ::= { hwEntityState 4 }
        
        hwMonitorInputEntry OBJECT-TYPE
            SYNTAX HwMonitorInputEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This is a replaceable unit physical entity."
        INDEX { hwMonitorInputIndex }
        ::= { hwMonitorInputTable 1 }
    
    HwMonitorInputEntry ::=
        SEQUENCE { 
                hwMonitorInputIndex
                    Integer32,
                hwMonitorInputName
                    DisplayString,
                hwMonitorInputState
                    HWLevelState,
                hwMonitorInputStateEnable
                    EnabledStatus,
                hwMonitorInputRowStatus
                    RowStatus
             }

        hwMonitorInputIndex OBJECT-TYPE
            SYNTAX Integer32 (1..4)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Monitor port index.
                 This is a number of input line,ranging from 1 to 4.
                "
            ::= { hwMonitorInputEntry 1 }
        
        hwMonitorInputName OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Monitor line name.
                "
            ::= { hwMonitorInputEntry 2 }
        
        hwMonitorInputState OBJECT-TYPE
            SYNTAX HWLevelState
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Monitor line status.  
                 The value is high or low.
                "
            ::= { hwMonitorInputEntry 3 }
        
        hwMonitorInputStateEnable OBJECT-TYPE
            SYNTAX EnabledStatus
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Enable monitor line. 
                "
            ::= { hwMonitorInputEntry 4 }
            
        hwMonitorInputRowStatus OBJECT-TYPE
            SYNTAX RowStatus                                     
            MAX-ACCESS read-create                           
            STATUS current                                   
            DESCRIPTION                                      
               "Status of monitor input row.
            "      
            ::= { hwMonitorInputEntry 5 }                
        

hwMonitorOutputTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwMonitorOutputEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table contains one row per replaceable unit physical entity.
                This table is used to create a output view."
            ::= { hwEntityState 5}
        
        hwMonitorOutputEntry OBJECT-TYPE
            SYNTAX HwMonitorOutputEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This is a replaceable unit physical entity."
        INDEX { hwMonitorOutputIndex, hwMonitorOutputRuleIndex }
        ::= { hwMonitorOutputTable 1 }
    
    HwMonitorOutputEntry ::=
        SEQUENCE { 
                hwMonitorOutputIndex
                    Integer32,
                hwMonitorOutputRuleIndex
                    Integer32,
                hwMonitorOutputMask
                    DisplayString,
                hwMonitorOutputKey
                    DisplayString,                
                hwMonitorOutputRowStatus
                    RowStatus  
             }

        hwMonitorOutputIndex OBJECT-TYPE
            SYNTAX Integer32 (1..3)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Monitor output view index. 
                 Through this index ,you can turn into the output view.
                "
            ::= { hwMonitorOutputEntry 1 }
            
        hwMonitorOutputRuleIndex OBJECT-TYPE
            SYNTAX Integer32 (1..16)
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Monitor output rule index. 
                 This is used to set the rules about all of the input line.
                "
            ::= { hwMonitorOutputEntry 2 }
            
            hwMonitorOutputMask OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Monitor output mask . 
                 This is used to matching the level of monitor input line.
                "
            ::= { hwMonitorOutputEntry 3 }
        
        hwMonitorOutputKey OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-create
            STATUS current
            DESCRIPTION
                "Normal level value of this output line.
                "
            ::= { hwMonitorOutputEntry 4 }            

        hwMonitorOutputRowStatus OBJECT-TYPE 
            SYNTAX RowStatus                
            MAX-ACCESS read-create          
            STATUS current                  
            DESCRIPTION                     
            "Status of monitor input row
            "                          
            ::= { hwMonitorOutputEntry 5 }
                             
hwEntPowerUsedInfoTable OBJECT-TYPE
    SYNTAX SEQUENCE OF HwEntPowerUsedInfoEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "A table of information that displays the power use of entity ."
    ::= { hwEntityState 6 }

    hwEntPowerUsedInfoEntry OBJECT-TYPE
        SYNTAX HwEntPowerUsedInfoEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "Entry of the table of information that displays the power use of entity."
        INDEX { entPhysicalIndex }
        ::= { hwEntPowerUsedInfoTable 1 }
        
    HwEntPowerUsedInfoEntry ::=
        SEQUENCE { 
            hwEntPowerUsedInfoBoardName
                OCTET STRING,
            hwEntPowerUsedInfoBoardType
                OCTET STRING,
            hwEntPowerUsedInfoBoardSlot
                Integer32,
            hwEntPowerUsedInfoPower
                Integer32
                }

        hwEntPowerUsedInfoBoardName OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Board name."
            ::= { hwEntPowerUsedInfoEntry 1 }
        
        hwEntPowerUsedInfoBoardType OBJECT-TYPE
            SYNTAX OCTET STRING
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Board type."
            ::= { hwEntPowerUsedInfoEntry 2 }
        
        hwEntPowerUsedInfoBoardSlot OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Board's slot number."
            ::= { hwEntPowerUsedInfoEntry 3 }
        
        hwEntPowerUsedInfoPower OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Used power of board."
            ::= { hwEntPowerUsedInfoEntry 4 }
--  **********************************************************
--  *         Vitrual Cable Test   ( Begin )                 *
--  **********************************************************
    hwVirtualCableTestTable OBJECT-TYPE
            SYNTAX SEQUENCE OF HwVirtualCableTestEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This table contains one row per replaceable unit physical entity.
                 This table is used to display VCT result."
            ::= { hwEntityState 7}
        
        hwVirtualCableTestEntry OBJECT-TYPE
            SYNTAX HwVirtualCableTestEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "This is a replaceable unit physical entity."
        INDEX { hwVirtualCableTestIfIndex}
        ::= { hwVirtualCableTestTable 1 }
    
    HwVirtualCableTestEntry ::=
        SEQUENCE { 
                hwVirtualCableTestIfIndex
                    InterfaceIndex,
                hwVirtualCableTestPairStatus
                    INTEGER,
                hwVirtualCableTestPairLength
                    Integer32    
             }

        hwVirtualCableTestIfIndex OBJECT-TYPE
            SYNTAX InterfaceIndex
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "IfIndex of port that you want to test cable."
            ::= { hwVirtualCableTestEntry 1 }
                        
    hwVirtualCableTestPairStatus OBJECT-TYPE
        SYNTAX INTEGER
            {
                    normal(1),
                    abnormalOpen(2),     
                    abnormalShort(3),
                    abnormalOpenShort(4),    
                    abnormalCrossTalk(5),
                    unknown(6),
                    notSupport(7)
                }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Pair status. 
             This indicate the status of cable.
             "
        ::= { hwVirtualCableTestEntry 2 }
        
        hwVirtualCableTestPairLength OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Pair Length.
                 This indicate the length of cable.
                "
            ::= { hwVirtualCableTestEntry 3 }            
      
--  **********************************************************
--  *         Vitrual Cable Test  ( End )                    *
--  **********************************************************
                             
--     Notifications
--  
        hwEntityExtTraps OBJECT IDENTIFIER ::= { hwEntityExtentMIB 2 }
        
        hwEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { hwEntityExtTraps 0 }
        
        hwEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE
            OBJECTS { hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                " The hwEntityEnvTemperatureThresholdNotification
                indicates the temperature have been exceed the threshold.
                In the condition, user should check the hardware and the 
                environment of the entity, sometimes it happened because
                of the failture of air-condition. Anyway, the threshold
                should lower than the value that most service work fine. "
            ::= { hwEntityExtTrapsPrefix 1 }
        
        hwEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE
            OBJECTS { hwEntityVoltage, hwEntityVoltageLowThreshold, hwEntityAdminStatus, hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                " The hwEntityExtVoltageLowThresholdNotification indicates
                the voltage is lower than the threshold. This may decrease
                the usability of the entity. If the voltage is lower too much 
                than the hardware needed, the entity will stop working. 
                Anyway, the threshold should higher than the value that 
                most service work fine. "
            ::= { hwEntityExtTrapsPrefix 2 }
        
        hwEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE
            OBJECTS { hwEntityVoltage, hwEntityVoltageHighThreshold, hwEntityAdminStatus, hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                " The hwEntityExtVoltageHighThresholdNotification indicates
                the voltage is higher than the threshold. This may decrease
                the usability of the entity. If the voltage is higher too much 
                than the hardware needed, the entity may be destroyed by the high
                voltage. Anyway, the threshold should lower than the value 
                that most service work fine. "
            ::= { hwEntityExtTrapsPrefix 3 }
        
        hwEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE
            OBJECTS { hwEntityCpuUsage, hwEntityCpuUsageThreshold, hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, 
                hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                " The hwEntityExtCpuUsageThresholdNotfication indicates
                the entity is overload, and the service running in the entity
                will not get the performance it should because of CPU's 
                performance. Anyway, the threshold should lower than the 
                value that most service work fine. "
            ::= { hwEntityExtTrapsPrefix 4 }
        
        hwEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE
            OBJECTS { hwEntityMemUsage, hwEntityMemUsageThreshold, hwEntityMemSize, hwEntityAdminStatus, hwEntityAlarmLight
                 }
            STATUS current
            DESCRIPTION 
                " The hwEntityExtMemUsageThresholdNotification indicates
                the entity is overload, and the service running in the entity
                will not get the performance it should because of lower 
                memory. Anyway, the threshold should lower than the 
                value that most service work fine. "
            ::= { hwEntityExtTrapsPrefix 5 }
        
        hwEntityExtOperEnabled NOTIFICATION-TYPE
            OBJECTS { hwEntityAdminStatus, hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                "The entity is operational. The entity this
                notification refers can be identified by
                extracting the entPhysicalIndex from one of the
                variable bindings."
            ::= { hwEntityExtTrapsPrefix 6 }
        
        hwEntityExtOperDisabled NOTIFICATION-TYPE
            OBJECTS { hwEntityAdminStatus, hwEntityAlarmLight }
            STATUS current
            DESCRIPTION 
                "The entity is operational. The entity this
                notification refers can be identified by
                extracting the entPhysicalIndex from one of the
                variable bindings."
            ::= { hwEntityExtTrapsPrefix 7 }

        hwEntityExtMonitorBoardAbnormalNotification NOTIFICATION-TYPE
            STATUS current
            DESCRIPTION 
                "The monitor board turns normal to abnormal."
            ::= { hwEntityExtTrapsPrefix 8 } 

        hwEntityExtMonitorBoardNormalNotification NOTIFICATION-TYPE
            STATUS current
            DESCRIPTION 
                "The monitor board turns abnormal to normal."
            ::= { hwEntityExtTrapsPrefix 9 }

        hwEntityExtMonitorPortAbnormalNotification NOTIFICATION-TYPE
            OBJECTS { hwMonitorInputState, hwMonitorInputName }
            STATUS current
            DESCRIPTION 
                "The monitor port turns normal to abnormal."
            ::= { hwEntityExtTrapsPrefix 10 }

        hwEntityExtMonitorPortNormalNotification NOTIFICATION-TYPE
            OBJECTS { hwMonitorInputState, hwMonitorInputName }
            STATUS current
            DESCRIPTION 
                "The monitor port turns abnormal to normal."
            ::= { hwEntityExtTrapsPrefix 11 }   
            
            hwEntityExtCpuUsageLowThresholdNotfication NOTIFICATION-TYPE
                OBJECTS { hwEntityCpuUsage, hwEntityCpuUsageThreshold, hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, 
                            hwEntityAlarmLight }
                STATUS current
                DESCRIPTION 
                    " The hwEntityExtCpuUsageThresholdNotfication indicates
                    the entity is overload, and the service running in the entity
                    will not get the performance it should because of CPU's 
                    performance. Anyway, the threshold should lower than the 
                    value that most service work fine. "
                ::= { hwEntityExtTrapsPrefix 12 }                
            
hwDevicePowerInfoObjects OBJECT IDENTIFIER ::= { hwEntityExtentMIB 3 }
    
    hwDevicePowerInfoTotalPower OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Device total power."
        ::= { hwDevicePowerInfoObjects 1 }
    
    hwDevicePowerInfoUsedPower OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Device used power."
        ::= { hwDevicePowerInfoObjects 2 }   

--     Conformance and Compliance
-- 
        hwEntityExtConformance OBJECT IDENTIFIER ::= { hwEntityExtentMIB 4 }
        
        hwEntityExtCompliances OBJECT IDENTIFIER ::= { hwEntityExtConformance 1 }
        
--  this module
        hwEntityExtCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION 
                "The compliance statement for systems supporting
                the HUAWEI Entity extent MIB."
            MODULE -- this module
            MANDATORY-GROUPS { hwEntityExtGroup }
            OBJECT hwEntityAdminStatus
                MIN-ACCESS read-only
                DESCRIPTION 
                    "Write access is not required."
            OBJECT hwEntityCpuUsageThreshold
                MIN-ACCESS read-only
                DESCRIPTION 
                    "Write access is not required."
            OBJECT hwEntityMemUsageThreshold
                MIN-ACCESS read-only
                DESCRIPTION 
                    "Write access is not required."
            OBJECT hwEntityTemperatureThreshold
                MIN-ACCESS read-only
                DESCRIPTION 
                    "Write access is not required."
            OBJECT hwEntityVoltageLowThreshold
                MIN-ACCESS read-only
                DESCRIPTION 
                    "Write access is not required."
                OBJECT hwEntityVoltageHighThreshold
                    MIN-ACCESS read-only
                    DESCRIPTION 
                        "Write access is not required."
            ::= { hwEntityExtCompliances 1 }
        
        hwEntityExtGroups OBJECT IDENTIFIER ::= { hwEntityExtConformance 2 }
        
        hwEntityExtGroup OBJECT-GROUP
            OBJECTS { hwEntityAdminStatus, hwEntityOperStatus, hwEntityStandbyStatus, hwEntityAlarmLight, hwEntityCpuUsage, 
                hwEntityCpuUsageThreshold, hwEntityMemUsage, hwEntityMemUsageThreshold, hwEntityMemSize, hwEntityUpTime, 
                hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityVoltage, hwEntityVoltageLowThreshold, hwEntityVoltageHighThreshold,
                hwEntityTemperatureLowThreshold, hwEntityOpticalPower, hwEntityCurrent, hwEntityMemSizeMega,hwEntityPortType,hwEntityDuplex,hwEntityOpticalPowerRx, hwEntityCpuUsageLowThreshold  }
            STATUS current
            DESCRIPTION 
                "Standard HUAWEI Entity Extent group."
            ::= { hwEntityExtGroups 1 }
        
        hwEntityExtNotificationGroup NOTIFICATION-GROUP
            NOTIFICATIONS { hwEntityExtTemperatureThresholdNotification, hwEntityExtVoltageLowThresholdNotification, hwEntityExtVoltageHighThresholdNotification, hwEntityExtCpuUsageThresholdNotfication, hwEntityExtMemUsageThresholdNotification, 
                hwEntityExtOperEnabled, hwEntityExtOperDisabled, hwEntityExtMonitorBoardAbnormalNotification,hwEntityExtMonitorBoardNormalNotification,hwEntityExtMonitorPortAbnormalNotification, hwEntityExtMonitorPortNormalNotification , hwEntityExtCpuUsageLowThresholdNotfication}
            STATUS current
            DESCRIPTION 
                "Standard HUAWEI Entity Extent Notification group."
            ::= { hwEntityExtGroups 2 }
        
        hwRUModuleInfoGroup OBJECT-GROUP
            OBJECTS { hwEntityBomId, hwEntityBomEnDesc, hwEntityManufacturedDate, hwEntityCLEICode, hwEntityArchivesInfoVersion, 
                hwEntityOpenBomId, hwEntityIssueNum, hwEntityBoardType }
            STATUS current
            DESCRIPTION 
                "Standard HUAWEI Entity Extent group."
            ::= { hwEntityExtGroups 3 }
        
        hwEntityExtOldObjectsGroup OBJECT-GROUP
            OBJECTS { hwEntityBomLocalDesc, hwEntityManufactureCode, hwEntityUpdateLog }
            STATUS obsolete
            DESCRIPTION 
                "Group for old objects that may be obsoleted."
            ::= { hwEntityExtGroups 4 }

        hwOpticalModuleInfoGroup OBJECT-GROUP
            OBJECTS { hwEntityOpticalMode, hwEntityOpticalWaveLength, hwEntityOpticalTransDistance, hwEntityOpticalVendorSn,hwEntityOpticalTemperature, hwEntityOpticalVoltage, hwEntityOpticalBiasCurrent, hwEntityOpticalRxPower, hwEntityOpticalTxPower }
            STATUS current
            DESCRIPTION 
                "Collection of objects that display the fiber module working information."
            ::= { hwEntityExtGroups 5 }        
        hwMonitorInputGroup OBJECT-GROUP
            OBJECTS { hwMonitorInputName, hwMonitorInputState, hwMonitorInputStateEnable, hwMonitorInputRowStatus }
            STATUS current
            DESCRIPTION 
                "Standard HUAWEI Entity Extent group."
            ::= { hwEntityExtGroups 6 }        
        hwMonitorOutputGroup OBJECT-GROUP
            OBJECTS { hwMonitorOutputMask, hwMonitorOutputKey, hwMonitorOutputRowStatus }
            STATUS current
            DESCRIPTION 
                "Standard HUAWEI Entity Extent group."
            ::= { hwEntityExtGroups 7 }
    
    hwEntPowerUsedInfoGroup OBJECT-GROUP
        OBJECTS { hwEntPowerUsedInfoBoardName, hwEntPowerUsedInfoBoardType, hwEntPowerUsedInfoBoardSlot, hwEntPowerUsedInfoPower }
        STATUS current
        DESCRIPTION 
            "Collection of objects that display the power informations of entity."
        ::= { hwEntityExtGroups 8 }
    
    hwDevicePowerInfoGroup OBJECT-GROUP
        OBJECTS { hwDevicePowerInfoTotalPower, hwDevicePowerInfoUsedPower }
        STATUS current
        DESCRIPTION 
            "Collection of objects that display the power informations of device."
        ::= { hwEntityExtGroups 9 }
        hwVirtualCableTestGroup OBJECT-GROUP
            OBJECTS { hwVirtualCableTestPairStatus, hwVirtualCableTestPairLength }
            STATUS current
            DESCRIPTION 
                "Collection of objects that display the status of cable."
            ::= { hwEntityExtGroups 10 }        
    END

--
-- HUAWEI-ENTITY-EXTENT-MIB.mib
--