--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-PMG828-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE,
             Counter32, Integer32, Unsigned32
        FROM SNMPv2-SMI
             DisplayString, RowStatus
        FROM SNMPv2-TC
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;

    pmG828 MODULE-IDENTITY
        LAST-UPDATED "201410070000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: tbd@siaemic.com
            "
        DESCRIPTION
            "Perforfamce Monitoring according to ITU-T G.829 for Radio Link
             and E1 Tributaries
             "
        REVISION "201410070000Z"
        DESCRIPTION
            "Changed MAX-ACCESS caluse of some object of pmG828TpClassTable
             from read-write to read-create
            "
        REVISION "201402030000Z"
        DESCRIPTION
            "Improved description of pmG828MibVersion
            "
        REVISION "201304160000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 11 }

----------------------------------------------------------------------------------
--  object identifier inside the module
----------------------------------------------------------------------------------

----------------------------------------------------------------------------------
--  pmG828 (PDH PERFORMANCE MONITORING G.828) GROUP
----------------------------------------------------------------------------------
--
--  The following objects are used to manage the Pdh G.828 Performance Monitoring
--  function.
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------

--
-------  The following table contains the records with  the counters used to evaluate
-------  the Performance Monitoring  of the radio according to G.828 specification.
-------  Begin of pmG828CounterTable
--
    pmG828MibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= {pmG828 1}

    pmG828CounterTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF    PmG828CounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmG828 records: one record for 1+0 configuration and two
             record for 1+1 configuration."
    ::= {pmG828 2}

    pmG828CounterRecord  OBJECT-TYPE
        SYNTAX      PmG828CounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmG828Counter record."
        INDEX {pmG828TPointId, pmG828CounterBlockId}
    ::= {pmG828CounterTable 1}

    PmG828CounterRecord  ::=
        SEQUENCE {
            pmG828TPointId            Integer32,
            pmG828CounterBlockId      Integer32,
            pmG828CounterBlockType    INTEGER,
            pmG828CounterBlockStatus  INTEGER,
            pmG828CounterTimeStamp    Unsigned32,
            pmG828BBECounter          Counter32,
            pmG828ESCounter           Counter32,
            pmG828SESCounter          Counter32,
            pmG828UASCounter          Counter32,
            pmG828SEPCounter          Counter32
        }

    pmG828TPointId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Termination Point."
    ::= {pmG828CounterRecord 1}

    pmG828CounterBlockId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the counters block and the counter type
             according to the following code:
              1  Current Daily counters
              2  Daily counters (Day before counters)
              3  Current 15 minutes counters
              4  15 minutes counters N. 1 (The most recent 15 minutes counters)
                  ..............................................
              n  15 minutes counters N. n
              20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before)."
    ::= {pmG828CounterRecord  2}

    pmG828CounterBlockType  OBJECT-TYPE
        SYNTAX      INTEGER {
                             daily       (1),
                             fifteenMin  (2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the counter block."
    ::= {pmG828CounterRecord 3}

    pmG828CounterBlockStatus  OBJECT-TYPE
        SYNTAX      INTEGER {
                             meaningless  (1),
                             meaningfull  (2),
                             incomplete   (3),
                             dummy        (4),
                             lost         (5),
                             restarted    (6)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Status of the block counter."
    ::= {pmG828CounterRecord 4}

    pmG828CounterTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed reported
             as the second number since 1-Gen-1970."
    ::= {pmG828CounterRecord 5}

    pmG828BBECounter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "G828 BBE counter."
    ::= {pmG828CounterRecord 6}

    pmG828ESCounter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "G828 Es counter."
    ::= {pmG828CounterRecord 7}

    pmG828SESCounter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "G828 SES counter."
    ::= {pmG828CounterRecord 8}

    pmG828UASCounter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "G828 UAS counter."
    ::= {pmG828CounterRecord 9}

    pmG828SEPCounter  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "G828 SEP counter."
    ::= {pmG828CounterRecord 10}

--
-------  End of pmG828CounterTable

--
-------  The following table contains the records used to manage the P.M. on both
-------  radio branch and the threshold cross alarms
-------  Begin of pmG828TpClassTable
--
    pmG828TpClassTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmG828TpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with PmG828TpClass records: one record for 1+0 configuration and
             two record for 1+1 configuration."
    ::= {pmG828 3}

    pmG828TpClassRecord  OBJECT-TYPE
        SYNTAX      PmG828TpClassRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmG828TpClass record."
        INDEX {pmG828TpClassId}
    ::= {pmG828TpClassTable 1}

    PmG828TpClassRecord  ::=
        SEQUENCE {
            pmG828TpClassId                Integer32,
            pmG828TpClassStartStop         INTEGER,
            pmG828TpClassLabel             DisplayString,
            pmG828TpClassTimeStamp         Unsigned32,
            pmG828TpClass15MEsAlarm        AlarmStatus,
            pmG828TpClass15MSesAlarm       AlarmStatus,
            pmG828TpClass15MSepAlarm       AlarmStatus,
            pmG828TpClass24HEsAlarm        AlarmStatus,
            pmG828TpClass24HSesAlarm       AlarmStatus,
            pmG828TpClass24HSepAlarm       AlarmStatus,
            pmG828TpClassUasAlarm          AlarmStatus,
            pmG828TpClass15MEsThreshold    Integer32,
            pmG828TpClass15MSesThreshold   Integer32,
            pmG828TpClass15MSepThreshold   Integer32,
            pmG828TpClass24HEsThreshold    Integer32,
            pmG828TpClass24HSesThreshold   Integer32,
            pmG828TpClass24HSepThreshold   Integer32,
            pmG828TpClassRowStatus         RowStatus
        }

    pmG828TpClassId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies the Termination Point."
    ::= {pmG828TpClassRecord 1}

    pmG828TpClassStartStop  OBJECT-TYPE
        SYNTAX      INTEGER {
                             start   (1),
                             stop    (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object is used to start and to stop the Perfomance Monitoring
             counter evaluation."
    ::= {pmG828TpClassRecord 2}

    pmG828TpClassLabel  OBJECT-TYPE
        SYNTAX      DisplayString    (SIZE(0..31))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "ASCII string used to identify  the Tp class:
             for example:
             pmG828TpClassBranchId = 1 label = Radio 1
             pmG828TpClassBranchId = 2 label = Radio 2
             pmG828TpClassBranchId = 3 label = Radio(switched)
             pmG828TpClassBranchId = 4 label = Trib E1 line side
             pmG828TpClassBranchId = 5 label = Trib E1 radio side."
    ::= {pmG828TpClassRecord 3}

    pmG828TpClassTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            ""
    ::= {pmG828TpClassRecord 4}

    pmG828TpClass15MEsAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes ES threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 5}

    pmG828TpClass15MSesAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes SES threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 6}

    pmG828TpClass15MSepAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "15 minutes SEP threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 7}

    pmG828TpClass24HEsAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily ES threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 8}

    pmG828TpClass24HSesAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily SES threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 9}

    pmG828TpClass24HSepAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Daily SEP threshold cross alarm with associated severity."
    ::= {pmG828TpClassRecord 10}

    pmG828TpClassUasAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "UAS alarm with associated severity."
    ::= {pmG828TpClassRecord 11}

    pmG828TpClass15MEsThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 12}

    pmG828TpClass15MSesThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 13}

    pmG828TpClass15MSepThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 14}

    pmG828TpClass24HEsThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of ES within one day to set pmG828TpClass24HEsAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 15}

    pmG828TpClass24HSesThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of SES within one day to set pmG828TpClass24HSesAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 16}

    pmG828TpClass24HSepThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of SEP within one day to set pmG828TpClass24HSepAlarm
             (zero value disables the alarm)."
        DEFVAL {0}
    ::= {pmG828TpClassRecord 17}

    pmG828TpClassRowStatus   OBJECT-TYPE 
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Status of this row of pmRxPwrTpClass.
            "
    ::= {pmG828TpClassRecord 18}

--
-------  End of pmG828TpClassTable

--
--  MAINTENANCE TABLE
--

-------  Begin of pmG828TpMaintTable
--
    pmG828TpMaintTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF     PmG828TpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with Command for maintenance of Termination Point.
             Objects in this table is not persistent. An Instance of this 
             table is created on creation of pmG828TpClassTable"
    ::= {pmG828 4}

    pmG828TpMaintRecord  OBJECT-TYPE
        SYNTAX      PmG828TpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "PmG828 Termination Point Maintenance record."
        INDEX {pmG828TpClassId}
    ::= {pmG828TpMaintTable 1}

    PmG828TpMaintRecord  ::=
        SEQUENCE {
            pmG828TpMaintCounterClear      INTEGER,
            pmG828TpMaintAlarmClear        INTEGER
        }

    pmG828TpMaintCounterClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring counters."
    ::= {pmG828TpMaintRecord 1}

    pmG828TpMaintAlarmClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the Perfomance Monitoring threshold cross alarms."
    ::= {pmG828TpMaintRecord 2}
--
-------  End of pmG828TpMaintTable

--
-------  The following objects are common to all instances.
--
    pmG828NSesSetUAS  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Number of SES (according G.828) to set UAS."
        DEFVAL {10}
    ::= {pmG828 5}

    pmG828NSesResetUAS  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Number of seconds whitout errors (according G.828) to reset UAS."
        DEFVAL {10}
    ::= {pmG828 6}

    pmG828TpClass15MEsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Defines the severity associated to the pmG828TpClass15MEsAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 7}

    pmG828TpClass15MSesAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClass15MSesAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 8}

    pmG828TpClass24HEsAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClass15MEsAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 9}

    pmG828TpClass24HSesAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClass15MSesAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 10}

    pmG828TpClassUASAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClassUASAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 11}

    pmG828TpClass15MSepAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClass15MSepAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 12}

    pmG828TpClass24HSepAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the pmG828TpClass24HSepAlarm and
             enables/disables the trap generation on status change event."
        DEFVAL {majorTrapEnable}
    ::= {pmG828 13}

------ End group -----------------------------------------------------------------

END