POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN

       IMPORTS
           MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32,
           Gauge32, Counter32, NOTIFICATION-TYPE
                   FROM SNMPv2-SMI
           TruthValue
                   FROM SNMPv2-TC
           MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
                   FROM SNMPv2-CONF

           SnmpAdminString
                    FROM SNMP-FRAMEWORK-MIB;

       powerEthernetMIB MODULE-IDENTITY
           LAST-UPDATED    "200311240000Z"  -- November 24, 2003
           ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
                         Working Group"

           CONTACT-INFO
               "WG Charter:http://www.ietf.org/html.charters/hubmib-charter.html
		Mailing lists:    
		General Discussion: hubmib@ietf.org
		      To Subscribe: hubmib-requests@ietf.org
		           In Body: subscribe your_email_address
			     Chair: Dan Romascanu
		Avaya
	        Tel:  +972-3-645-8414
        	Email: dromasca@avaya.com

	        Editor: Avi Berger
	        PowerDsine Inc.
        	Tel:    972-9-7755100 Ext 307
	        Fax:    972-9-7755120
        	E-mail: avib@PowerDsine.com
	       "
	   DESCRIPTION
           "The MIB module for managing Power Source Equipment
           (PSE) working according to the IEEE 802.af Powered
           Ethernet (DTE Power via MDI) standard.

           The following terms are used throughout this
           MIB module.  For complete formal definitions,
           the IEEE 802.3 standards should be consulted
           wherever possible:

           Group - A recommended, but optional, entity
           defined by the IEEE 802.3 management standard,
           in order to support a modular numbering scheme.
           The classical example allows an implementor to
           represent field-replaceable units as groups of
           ports, with the port numbering matching the
           modular hardware implementation.

           Port - This entity identifies the port within the group
           for which this entry contains information.  The numbering
           scheme for ports is implementation specific.
           Copyright (c) The Internet Society (2003).  This version
           of this MIB module is part of RFC 3621; See the RFC
           itself for full legal notices."


           REVISION    "200311240000Z"  -- November 24, 2003
           DESCRIPTION "Initial version, published as RFC 3621."
       ::= { mib-2 105 }

       pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 }
       pethObjects       OBJECT IDENTIFIER ::= { powerEthernetMIB 1 }
       pethConformance   OBJECT IDENTIFIER ::= { powerEthernetMIB 2 }

       -- PSE Objects

       pethPsePortTable OBJECT-TYPE
           SYNTAX      SEQUENCE OF PethPsePortEntry
           MAX-ACCESS  not-accessible
	   STATUS      current
	   DESCRIPTION
           "A table of objects that display and control the power
           characteristics of power Ethernet ports on a Power Source
           Entity (PSE) device.  This group will be implemented in
           managed power Ethernet switches and mid-span devices.
           Values of all read-write objects in this table are
           persistent at restart/reboot."
                      
       ::= { pethObjects 1 }

       pethPsePortEntry OBJECT-TYPE
           SYNTAX      PethPsePortEntry
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "A set of objects that display and control the power
           characteristics of a power Ethernet PSE port."
       INDEX    { pethPsePortGroupIndex , pethPsePortIndex  }
       ::= { pethPsePortTable 1 }

       PethPsePortEntry ::= SEQUENCE {
           pethPsePortGroupIndex
           Integer32,
           pethPsePortIndex
           Integer32,
           pethPsePortAdminEnable
           TruthValue,
           pethPsePortPowerPairsControlAbility
           TruthValue,
           pethPsePortPowerPairs
           INTEGER,
           pethPsePortDetectionStatus
           INTEGER,
           pethPsePortPowerPriority
           INTEGER,
           pethPsePortMPSAbsentCounter
           Counter32,
           pethPsePortType
           SnmpAdminString,
	   pethPsePortPowerClassifications
           INTEGER,
           pethPsePortInvalidSignatureCounter
           Counter32,
           pethPsePortPowerDeniedCounter
           Counter32,
           pethPsePortOverLoadCounter
           Counter32,
           pethPsePortShortCounter
           Counter32
       }

       pethPsePortGroupIndex OBJECT-TYPE
           SYNTAX      Integer32 (1..2147483647)
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "This variable uniquely identifies the group
           containing the port to which a power Ethernet PSE is
           connected.  Group means box in the stack, module in a
           rack and the value 1 MUST be used for non-modular devices.
           Furthermore, the same value MUST be used in this variable,
           pethMainPseGroupIndex, and pethNotificationControlGroupIndex
           to refer to a given box in a stack or module in the rack."
       ::= { pethPsePortEntry 1 }

       pethPsePortIndex OBJECT-TYPE
           SYNTAX      Integer32 (1..2147483647)
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "This variable uniquely identifies the power Ethernet PSE
           port within group pethPsePortGroupIndex to which the
           power Ethernet PSE entry is connected."
       ::= { pethPsePortEntry 2 }

       pethPsePortAdminEnable OBJECT-TYPE
           SYNTAX TruthValue
            MAX-ACCESS read-write
           STATUS current
           DESCRIPTION
           "true (1) An interface which can provide the PSE functions.
           false(2) The interface will act as it would if it had no PSE
           function."

       REFERENCE
       "IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState"
       ::= { pethPsePortEntry 3 }

       pethPsePortPowerPairsControlAbility OBJECT-TYPE
           SYNTAX TruthValue
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "Describes the capability of controlling the power pairs
           functionality to switch pins for sourcing power.
           The value true indicate that the device has the capability
           to control the power pairs.  When false the PSE Pinout
           Alternative used cannot be controlled through the
           PethPsePortAdminEnable attribute."
       REFERENCE
       "IEEE Std 802.3af Section 30.9.1.1.3
       aPSEPowerPairsControlAbility"
       ::= { pethPsePortEntry 4 }

       pethPsePortPowerPairs OBJECT-TYPE
           SYNTAX INTEGER   {
               signal(1),
               spare(2)
           }
            MAX-ACCESS read-write
           STATUS current
           DESCRIPTION
           "Describes or controls the pairs in use.  If the value of
           pethPsePortPowerPairsControl is true, this object is
           writable.
           A value of signal(1) means that the signal pairs
           only are in use.
           A value of spare(2) means that the spare pairs
           only are in use."
           REFERENCE
           "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
       ::= { pethPsePortEntry 5 }

       pethPsePortDetectionStatus OBJECT-TYPE
           SYNTAX INTEGER   {
               disabled(1),
               searching(2),
               deliveringPower(3),
               fault(4),
               test(5),
               otherFault(6)
           }
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "Describes the operational status of the port PD detection.
           A value of disabled(1)- indicates that the PSE State diagram
           is in the state DISABLED.
           A value of deliveringPower(3) - indicates that the PSE State
           diagram is in the state POWER_ON for a duration greater than
           tlim max (see IEEE Std 802.3af Table 33-5 tlim).
           A value of fault(4) - indicates that the PSE State diagram is
           in the state TEST_ERROR.
           A value of test(5) - indicates that the PSE State diagram is
           in the state TEST_MODE.
           A value of otherFault(6) - indicates that the PSE State
           diagram is in the state IDLE due to the variable
           error_conditions.
           A value of searching(2)- indicates the PSE State diagram is
           in a state other than those listed above."
           REFERENCE
           "IEEE Std 802.3af Section 30.9.1.1.5
           aPSEPowerDetectionStatus"
       ::= { pethPsePortEntry 6 }

       pethPsePortPowerPriority OBJECT-TYPE
           SYNTAX INTEGER   {
               critical(1),
               high(2),
               low(3)
           }
            MAX-ACCESS read-write
           STATUS current
           DESCRIPTION
           "This object controls the priority of the port from the point
           of view of a power management algorithm.  The priority that
           is set by this variable could be used by a control mechanism
           that prevents over current situations by disconnecting first
           ports with lower power priority.  Ports that connect devices
           critical to the operation of the network - like the E911
           telephones ports - should be set to higher priority."
       ::= { pethPsePortEntry 7 }

       pethPsePortMPSAbsentCounter OBJECT-TYPE
           SYNTAX Counter32
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "This counter is incremented when the PSE state diagram
           transitions directly from the state POWER_ON to the
           state IDLE due to tmpdo_timer_done being asserted."
       REFERENCE
       "IEEE Std 802.3af Section 30.9.1.1.11
        aPSEMPSAbsentCounter"
       ::= { pethPsePortEntry 8 }

       pethPsePortType OBJECT-TYPE
           SYNTAX SnmpAdminString
            MAX-ACCESS read-write
           STATUS current
           DESCRIPTION
           "A manager will set the value of this variable to indicate
           the type of powered device that is connected to the port.
           The default value supplied by the agent if no value has
           ever been set should be a zero-length octet string."
       ::= { pethPsePortEntry 9 }

       pethPsePortPowerClassifications OBJECT-TYPE
           SYNTAX INTEGER   {
               class0(1),
               class1(2),
               class2(3),
               class3(4),
               class4(5)
           }
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "Classification is a way to tag different terminals on the
           Power over LAN network according to their power consumption.
           Devices such as IP telephones, WLAN access points and others,
           will be classified according to their power requirements.
           The meaning of the classification labels is defined in the
           IEEE specification.

           This variable is valid only while a PD is being powered,
           that is, while the attribute pethPsePortDetectionStatus
           is reporting the enumeration deliveringPower."
           REFERENCE
           "IEEE Std 802.3af Section 30.9.1.1.6
           aPSEPowerClassification"
       ::=  { pethPsePortEntry 10 }

       pethPsePortInvalidSignatureCounter OBJECT-TYPE
           SYNTAX Counter32
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "This counter is incremented when the PSE state diagram
           enters the state SIGNATURE_INVALID."
           REFERENCE
           "IEEE Std 802.3af Section 30.9.1.1.7
           aPSEInvalidSignatureCounter"
       ::= { pethPsePortEntry 11 }

       pethPsePortPowerDeniedCounter OBJECT-TYPE
           SYNTAX Counter32
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
           "This counter is incremented when the PSE state diagram
           enters the state POWER_DENIED."
	   REFERENCE
       	   "IEEE Std 802.3af Section 30.9.1.1.8
	    aPSEPowerDeniedCounter"
       ::= { pethPsePortEntry 12 }

       pethPsePortOverLoadCounter OBJECT-TYPE
           SYNTAX Counter32
	   MAX-ACCESS read-only
	   STATUS current
	   DESCRIPTION
           "This counter is incremented when the PSE state diagram
           enters the state ERROR_DELAY_OVER."
	   REFERENCE
	   "IEEE Std 802.3af Section 30.9.1.1.9
	    aPSEOverLoadCounter"
       ::= { pethPsePortEntry 13 }

       pethPsePortShortCounter OBJECT-TYPE
           SYNTAX Counter32
	   MAX-ACCESS read-only
	   STATUS current
	   DESCRIPTION
           "This counter is incremented when the PSE state diagram
            enters the state ERROR_DELAY_SHORT."
	    REFERENCE
	    "IEEE Std 802.3af Section 30.9.1.1.10
	     aPSEShortCounter"
       ::= { pethPsePortEntry 14 }

       -- Main PSE Objects

       pethMainPseObjects       OBJECT IDENTIFIER ::= { pethObjects 3 }

       pethMainPseTable OBJECT-TYPE
           SYNTAX      SEQUENCE OF PethMainPseEntry
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "A table of objects that display and control attributes
           of the main power source in a PSE  device.  Ethernet
           switches are one example of boxes that would support
           these objects.
           Values of all read-write objects in this table are
           persistent at restart/reboot."
       ::= { pethMainPseObjects 1 }

       pethMainPseEntry OBJECT-TYPE
           SYNTAX      PethMainPseEntry
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "A set of objects that display and control the Main
           power of a PSE. "
       INDEX    { pethMainPseGroupIndex }
       ::= { pethMainPseTable 1 }

       PethMainPseEntry ::= SEQUENCE {
           pethMainPseGroupIndex
           Integer32,
           pethMainPsePower
           Gauge32 ,
           pethMainPseOperStatus
           INTEGER,
           pethMainPseConsumptionPower
           Gauge32,
           pethMainPseUsageThreshold
           Integer32
       }
       
       pethMainPseGroupIndex OBJECT-TYPE
           SYNTAX       Integer32 (1..2147483647)
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "This variable uniquely identifies the group to which
           power Ethernet PSE is connected.  Group means (box in
           the stack, module in a rack) and the value 1 MUST be
           used for non-modular devices.  Furthermore, the same
           value MUST be used in this variable, pethPsePortGroupIndex,
           and pethNotificationControlGroupIndex to refer to a
           given box in a stack or module in a rack."
       ::= { pethMainPseEntry 1 }


       pethMainPsePower OBJECT-TYPE
           SYNTAX      Gauge32  (1..65535)
           UNITS      "Watts"
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
           "The nominal power of the PSE expressed in Watts."
       ::= { pethMainPseEntry 2 }

       pethMainPseOperStatus OBJECT-TYPE
           SYNTAX INTEGER   {
               on(1),
               off(2),
               faulty(3)
          }
	  MAX-ACCESS  read-only
	  STATUS      current
	  DESCRIPTION
          "The operational status of the main PSE."
       ::= { pethMainPseEntry 3 }

       pethMainPseConsumptionPower OBJECT-TYPE
           SYNTAX      Gauge32
           UNITS      "Watts"
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
           "Measured usage power expressed in Watts."
       ::= { pethMainPseEntry 4 }

       pethMainPseUsageThreshold OBJECT-TYPE
           SYNTAX      Integer32  (1..99)
           UNITS      "%"
            MAX-ACCESS  read-write
           STATUS      current
           DESCRIPTION
           "The usage threshold expressed in percents for
           comparing the measured power and initiating
           an alarm if the threshold is exceeded."
       ::= { pethMainPseEntry 5 }

       -- Notification  Control  Objects

       pethNotificationControl        OBJECT IDENTIFIER ::= { pethObjects 4 }

       pethNotificationControlTable OBJECT-TYPE
           SYNTAX      SEQUENCE OF PethNotificationControlEntry
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "A table of objects that display and control the
            Notification on a PSE  device.
            Values of all read-write objects in this table are
            persistent at restart/reboot."
       ::= { pethNotificationControl 1 }

       pethNotificationControlEntry OBJECT-TYPE
           SYNTAX      PethNotificationControlEntry
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "A set of objects that control the Notification events."
           INDEX    { pethNotificationControlGroupIndex }
       ::= { pethNotificationControlTable 1 }

       PethNotificationControlEntry ::= SEQUENCE {
           pethNotificationControlGroupIndex
           Integer32,
           pethNotificationControlEnable
           TruthValue
       }
 
      pethNotificationControlGroupIndex OBJECT-TYPE
           SYNTAX      Integer32 (1..2147483647)
           MAX-ACCESS  not-accessible
           STATUS      current
           DESCRIPTION
           "This variable uniquely identifies the group.  Group
           means box in the stack, module in a rack and the value
           1 MUST be used for non-modular devices.  Furthermore,
           the same value MUST be used in this variable,
           pethPsePortGroupIndex, and
           pethMainPseGroupIndex to refer to a given box in a
           stack or module in a rack. "
       ::= { pethNotificationControlEntry 1 }

       pethNotificationControlEnable  OBJECT-TYPE
           SYNTAX             TruthValue
            MAX-ACCESS         read-write
           STATUS             current
           DESCRIPTION
           "This object controls, on a per-group basis, whether
           or not notifications from the agent are enabled.  The
           value true(1) means that notifications are enabled; the
           value false(2) means that they are not."
       ::= { pethNotificationControlEntry 2 }



       --
       -- Notifications Section
       --
       --

       pethPsePortOnOffNotification NOTIFICATION-TYPE
           OBJECTS     { pethPsePortDetectionStatus }
           STATUS      current
           DESCRIPTION
           "This Notification indicates if Pse Port is delivering or
           not power to the PD.  This Notification SHOULD be sent on
           every status change except in the searching mode.
           At least 500 msec must elapse between notifications
           being emitted by the same object instance."
       ::= { pethNotifications 1 }

       pethMainPowerUsageOnNotification NOTIFICATION-TYPE
           OBJECTS     { pethMainPseConsumptionPower  }
           STATUS      current
           DESCRIPTION
           "This Notification indicate PSE Threshold usage
           indication is on, the usage power is above the
           threshold.  At least 500 msec must elapse between
           notifications being emitted by the same object
           instance."
       ::= { pethNotifications 2 }

       pethMainPowerUsageOffNotification NOTIFICATION-TYPE
           OBJECTS     { pethMainPseConsumptionPower }
           STATUS      current
           DESCRIPTION
           " This Notification indicates PSE Threshold usage indication
           off, the usage power is below the threshold.
           At least 500 msec must elapse between notifications being
           emitted by the same object instance."
       ::= { pethNotifications 3 }

       --
       -- Conformance Section
       --
       pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 }
       pethGroups      OBJECT IDENTIFIER ::= { pethConformance 2 }

       pethCompliance MODULE-COMPLIANCE
           STATUS  current
           DESCRIPTION
           "Describes the requirements for conformance to the
           Power Ethernet MIB."
           
       MODULE  -- this module
       MANDATORY-GROUPS { 
           pethPsePortGroup,
           pethPsePortNotificationGroup,
           pethNotificationControlGroup
           }
           GROUP   pethMainPseGroup
           DESCRIPTION
           "The pethMainPseGroup is mandatory for PSE systems
           that implement a main power supply."
           
	   GROUP   pethMainPowerNotificationGroup
           DESCRIPTION
               "The pethMainPowerNotificationGroup is mandatory for
               PSE systems that implement a main power supply."
       ::= { pethCompliances 1 }

       pethPsePortGroup OBJECT-GROUP
           OBJECTS {
	   pethPsePortAdminEnable,
           pethPsePortPowerPairsControlAbility,
           pethPsePortPowerPairs,
           pethPsePortDetectionStatus,
           pethPsePortPowerPriority,
	   pethPsePortMPSAbsentCounter,
	   pethPsePortInvalidSignatureCounter,
	   pethPsePortPowerDeniedCounter,
           pethPsePortOverLoadCounter,
           pethPsePortShortCounter,
           pethPsePortType,
           pethPsePortPowerClassifications
           }
	   STATUS  current
           DESCRIPTION
           "PSE Port objects."
       ::= { pethGroups 1 }

       pethMainPseGroup OBJECT-GROUP
           OBJECTS {
           pethMainPsePower,
           pethMainPseOperStatus,
           pethMainPseConsumptionPower,
           pethMainPseUsageThreshold
           }
          STATUS  current
          DESCRIPTION
          "Main PSE Objects. "
       ::= { pethGroups 2 }

       pethNotificationControlGroup OBJECT-GROUP
           OBJECTS {
           pethNotificationControlEnable
           }
	   STATUS  current
	   DESCRIPTION
           "Notification Control  Objects. "
       ::= { pethGroups 3 }

       pethPsePortNotificationGroup NOTIFICATION-GROUP
           NOTIFICATIONS { pethPsePortOnOffNotification}
           STATUS           current
           DESCRIPTION  "Pse Port Notifications."
       ::= { pethGroups 4 }

       pethMainPowerNotificationGroup NOTIFICATION-GROUP
           NOTIFICATIONS { 
           pethMainPowerUsageOnNotification,
           pethMainPowerUsageOffNotification
	   }
	   STATUS           current
	   DESCRIPTION  "Main PSE Notifications."
       ::= { pethGroups 5 }