#!/usr/local/bin/python3.8
# -*- coding: UTF-8 -*-
#
# Script for checking global health of host running VMware ESX/ESXi
#
# Licence : GNU General Public Licence (GPL) http://www.gnu.org/
# This program is free software; you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation; either version 2
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, see <https://www.gnu.org/licenses/>.
#
# Pre-req : pywbem
#
# Copyright (c) 2008 David Ligeret
# Copyright (c) 2009 Joshua Daniel Franklin
# Copyright (c) 2010 Branden Schneider
# Copyright (c) 2010-2021 Claudio Kuenzler
# Copyright (c) 2010 Samir Ibradzic
# Copyright (c) 2010 Aaron Rogers
# Copyright (c) 2011 Ludovic Hutin
# Copyright (c) 2011 Carsten Schoene
# Copyright (c) 2011-2012 Phil Randal
# Copyright (c) 2011 Fredrik Aslund
# Copyright (c) 2011 Bertrand Jomin
# Copyright (c) 2011 Ian Chard
# Copyright (c) 2012 Craig Hart
# Copyright (c) 2013 Carl R. Friend
# Copyright (c) 2015 Andreas Gottwald
# Copyright (c) 2015 Stanislav German-Evtushenko
# Copyright (c) 2015 Stefan Roos
# Copyright (c) 2018 Peter Newman
# Copyright (c) 2020 Luca Berra
#
# The VMware 4.1 CIM API is documented here:
#   http://www.vmware.com/support/developer/cim-sdk/4.1/smash/cim_smash_410_prog.pdf
#   http://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/
#
# The VMware 5.5 and above CIM API is documented here:
#   https://code.vmware.com/apis/207/cim
#
# This monitoring plugin is maintained and documented here:
#   https://www.claudiokuenzler.com/monitoring-plugins/check_esxi_hardware.php
#
#@---------------------------------------------------
#@ History
#@---------------------------------------------------
#@ Date   : 20080820
#@ Author : David Ligeret
#@ Reason : Initial release
#@---------------------------------------------------
#@ Date   : 20080821
#@ Author : David Ligeret
#@ Reason : Add verbose mode
#@---------------------------------------------------
#@ Date   : 20090219
#@ Author : Joshua Daniel Franklin
#@ Reason : Add try/except to catch AuthError and CIMError
#@---------------------------------------------------
#@ Date   : 20100202
#@ Author : Branden Schneider
#@ Reason : Added HP Support (HealthState)
#@---------------------------------------------------
#@ Date   : 20100512
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Combined different versions (Joshua and Branden)
#@ Reason : Added hardware type switch (dell or hp)
#@---------------------------------------------------
#@ Date   : 20100626/28
#@ Author : Samir Ibradzic www.brastel.com
#@ Reason : Added basic server info
#@ Reason : Wanted to have server name, serial number & bios version at output
#@ Reason : Set default return status to Unknown
#@---------------------------------------------------
#@ Date   : 20100702
#@ Author : Aaron Rogers www.cloudmark.com
#@ Reason : GlobalStatus was incorrectly getting (re)set to OK with every CIM element check
#@---------------------------------------------------
#@ Date   : 20100705
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Due to change 20100702 all Dell servers would return UNKNOWN instead of OK...
#@ Reason : ... so added Aaron's logic at the end of the Dell checks as well
#@---------------------------------------------------
#@ Date   : 20101028
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Changed text in Usage and Example so people dont forget to use https://
#@---------------------------------------------------
#@ Date   : 20110110
#@ Author : Ludovic Hutin (Idea and Coding) / Claudio Kuenzler (Bugfix)
#@ Reason : If Dell Blade Servers are used, Serial Number of Chassis was returned
#@---------------------------------------------------
#@ Date   : 20110207
#@ Author : Carsten Schoene carsten.schoene.cc
#@ Reason : Bugfix for Intel systems (in this case Intel SE7520) - use 'intel' as system type
#@---------------------------------------------------
#@ Date   : 20110215
#@ Author : Ludovic Hutin
#@ Reason : Plugin now catches Socket Error (Timeout Error) and added a timeout parameter
#@---------------------------------------------------
#@ Date   : 20110217/18
#@ Author : Ludovic Hutin / Tom Murphy
#@ Reason : Bugfix in Socket Error if clause
#@---------------------------------------------------
#@ Date   : 20110221
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Remove recently added Timeout due to incompabatility on Windows
#@ Reason : and changed name of plugin to check_esxi_hardware
#@---------------------------------------------------
#@ Date   : 20110426
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Added 'ibm' hardware type (compatible to Dell output). Tested by Keith Erekson.
#@---------------------------------------------------
#@ Date   : 20110426
#@ Author : Phil Randal
#@ Reason : URLise Dell model and tag numbers (as in check_openmanage)
#@ Reason : Return performance data (as in check_openmanage, using similar names where possible)
#@ Reason : Minor code tidyup - use elementName instead of instance['ElementName']
#@---------------------------------------------------
#@ Date   : 20110428
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : If hardware type is specified as 'auto' try to autodetect vendor
#@ Reason : Return performance data for some HP models
#@ Reason : Indent 'verbose' output to make it easier to read
#@ Reason : Use OptionParser to give better parameter parsing (retaining compatability with original)
#@---------------------------------------------------
#@ Date   : 20110503
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix bug in HP Virtual Fan percentage output
#@ Reason : Slight code reorganisation
#@ Reason : Sort performance data
#@ Reason : Fix formatting of current output
#@---------------------------------------------------
#@ Date   : 20110504
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Minor code changes and documentation improvements
#@ Reason : Remove redundant mismatched ' character in performance data output
#@ Reason : Output non-integral values for all sensors to fix problem seen with system board voltage sensors
#@          on an IBM server (thanks to Attilio Drei for the sample output)
#@---------------------------------------------------
#@ Date   : 20110505
#@ Author : Fredrik Aslund
#@ Reason : Added possibility to use first line of a file as password (file:)
#@---------------------------------------------------
#@ Date   : 20110505
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Simplfy 'verboseoutput' to use 'verbose' as global variable instead of as parameter
#@ Reason : Don't look at performance data from CIM_NumericSensor if we're not using it
#@ Reason : Add --no-power, --no-volts, --no-current, --no-temp, and --no-fan options
#@---------------------------------------------------
#@ Date   : 20110506
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Reinstate timeouts with --timeout parameter (but not on Windows)
#@ Reason : Allow file:passwordfile in old-style arguments too
#@---------------------------------------------------
#@ Date   : 20110507
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : On error, include numeric sensor value in output
#@---------------------------------------------------
#@ Date   : 20110520
#@ Author : Bertrand Jomin
#@ Reason : Plugin had problems to handle some S/N from IBM Blade Servers
#@---------------------------------------------------
#@ Date   : 20110614
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Rewrote file handling and file can now be used for user AND password
#@---------------------------------------------------
#@ Date   : 20111003
#@ Author : Ian Chard (ian@chard.org)
#@ Reason : Allow a list of unwanted elements to be specified, which is useful
#@          in cases where hardware isn't well supported by ESXi
#@---------------------------------------------------
#@ Date   : 20120402
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Making plugin GPL compatible (Copyright) and preparing for OpenBSD port
#@---------------------------------------------------
#@ Date   : 20120405
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix lookup of warranty info for Dell
#@---------------------------------------------------
#@ Date   : 20120501
#@ Author : Craig Hart
#@ Reason : Bugfix in manufacturer discovery when cim entry not found or empty
#@---------------------------------------------------
#@ Date   : 20121027
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added workaround for Dell PE x620 where "System Board 1 Riser Config Err 0: Connected"
#@          element outputs wrong return code. Dell, please fix that.
#@          Added web-link to VMware CIM API 5.x at top of script.
#@---------------------------------------------------
#@ Date   : 20130424
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Another workaround for Dell systems "System Board 1 LCD Cable Pres 0: Connected"
#@---------------------------------------------------
#@ Date   : 20130702
#@ Author : Carl R. Friend
#@ Reason : Improving wrong authentication timeout and exit UNKNOWN
#@---------------------------------------------------
#@ Date   : 20130725
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix lookup of warranty info for Dell
#@---------------------------------------------------
#@ Date   : 20140319
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Another two workarounds for Dell systems (VGA Cable Pres 0, Add-in Card 4 PEM Presence 0)
#@---------------------------------------------------
#@ Date   : 20150109
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Output serial number of chassis if a blade server is checked
#@---------------------------------------------------
#@ Date   : 20150119
#@ Author : Andreas Gottwald
#@ Reason : Fix NoneType element bug
#@---------------------------------------------------
#@ Date   : 20150626
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added support for patched pywbem 0.7.0 and new version 0.8.0, handle SSL error exception
#@---------------------------------------------------
#@ Date   : 20150710
#@ Author : Stanislav German-Evtushenko
#@ Reason : Exit Unknown instead of Critical for timeouts and auth errors
#@---------------------------------------------------
#@ Date   : 20151111
#@ Author : Stefan Roos
#@ Reason : Removed unused sensor_value variable and string import.
#@ Reason : Added global hosturl variable declaration after imports.
#@---------------------------------------------------
#@ Date   : 20160411
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Distinguish between pywbem 0.7 and 0.8 (which is now released)
#@---------------------------------------------------
#@ Date   : 20160531
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Add parameter for variable CIM port (useful when behind NAT)
#@---------------------------------------------------
#@ Date   : 20161013
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added support for pywbem 0.9.x (and upcoming releases)
#@---------------------------------------------------
#@ Date   : 20170905
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added option to ignore LCD/Display related elements (--no-lcd)
#@---------------------------------------------------
#@ Date   : 20180329
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Try to use internal pywbem function to determine version
#@---------------------------------------------------
#@ Date   : 20180411
#@ Author : Peter Newman
#@ Reason : Throw an unknown if we can't fetch the data for some reason
#@---------------------------------------------------
#@ Date   : 20181001
#@ Author : Claudio Kuenzler
#@ Reason : python3 compatibility
#@---------------------------------------------------
#@ Date   : 20190510
#@ Author : Claudio Kuenzler
#@ Reason : Allow regular expressions from ignore list (-r)
#@---------------------------------------------------
#@ Date   : 20190701
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix lookup of warranty info for Dell (again)
#@---------------------------------------------------
#@ Date   : 20200605
#@ Author : Luca Berra
#@ Reason : Add option to ignore chassis intrusion (Supermicro)
#@---------------------------------------------------
#@ Date   : 20200605
#@ Author : Claudio Kuenzler
#@ Reason : Add parameter (-S) for custom SSL/TLS protocol version
#@---------------------------------------------------
#@ Date   : 20200710
#@ Author : Claudio Kuenzler
#@ Reason : Improve missing mandatory parameter error text (issue #47)
#@          Delete temporary openssl config file after use (issue #48)
#@---------------------------------------------------
#@ Date   : 20210809
#@ Author : Claudio Kuenzler
#@ Reason : Fix TLSv1 usage (issue #51)
#@---------------------------------------------------


from __future__ import print_function
import sys
import time
import pywbem
import re
import pkg_resources
from optparse import OptionParser,OptionGroup

version = '20210809'

NS = 'root/cimv2'
hosturl = ''

# define classes to check 'OperationStatus' instance
ClassesToCheck = [
  'OMC_SMASHFirmwareIdentity',
  'CIM_Chassis',
  'CIM_Card',
  'CIM_ComputerSystem',
  'CIM_NumericSensor',
  'CIM_Memory',
  'CIM_Processor',
  'CIM_RecordLog',
  'OMC_DiscreteSensor',
  'OMC_Fan',
  'OMC_PowerSupply',
  'VMware_StorageExtent',
  'VMware_Controller',
  'VMware_StorageVolume',
  'VMware_Battery',
  'VMware_SASSATAPort'
]

sensor_Type = {
  0:'unknown',
  1:'Other',
  2:'Temperature',
  3:'Voltage',
  4:'Current',
  5:'Tachometer',
  6:'Counter',
  7:'Switch',
  8:'Lock',
  9:'Humidity',
  10:'Smoke Detection',
  11:'Presence',
  12:'Air Flow',
  13:'Power Consumption',
  14:'Power Production',
  15:'Pressure',
  16:'Intrusion',
  32768:'DMTF Reserved',
  65535:'Vendor Reserved'
}

data = []

perf_Prefix = {
  1:'Pow',
  2:'Vol',
  3:'Cur',
  4:'Tem',
  5:'Fan',
  6:'FanP'
}


# parameters

# host name
hostname=''

# cim port
cimport=''

# user
user=''

# password
password=''

# vendor - possible values are 'unknown', 'auto', 'dell', 'hp', 'ibm', 'intel'
vendor='unknown'

# verbose
verbose=False

# Produce performance data output for nagios
perfdata=False

# timeout
timeout = 0

# elements to ignore (full SEL, broken BIOS, etc)
ignore_list=[]
regex_ignore_list=[]
regex=False

# urlise model and tag numbers (currently only Dell supported, but the code does the right thing for other vendors)
urlise_country=''

# collect perfdata for each category
get_power   = True
get_volts   = True
get_current = True
get_temp    = True
get_fan     = True
get_lcd     = True
get_intrusion = True

# define exit codes
ExitOK = 0
ExitWarning = 1
ExitCritical = 2
ExitUnknown = 3

# Special handling for blade servers
isblade = "no"

def dell_country(country):
  if country == 'at':  # Austria
    return 'at/de/'
  if country == 'be':  # Belgium
    return 'be/nl/'
  if country == 'cz':  # Czech Republic
    return 'cz/cs/'
  if country == 'de':  # Germany
    return 'de/de/'
  if country == 'dk':  # Denmark
    return 'dk/da/'
  if country == 'es':  # Spain
    return 'es/es/'
  if country == 'fi':  # Finland
    return 'fi/fi/'
  if country == 'fr':  # France
    return 'fr/fr/'
  if country == 'gr':  # Greece
    return 'gr/en/'
  if country == 'it':  # Italy
    return 'it/it/'
  if country == 'il':  # Israel
    return 'il/en/'
  if country == 'me':  # Middle East
    return 'me/en/'
  if country == 'no':  # Norway
    return 'no/no/'
  if country == 'nl':  # The Netherlands
    return 'nl/nl/'
  if country == 'pl':  # Poland
    return 'pl/pl/'
  if country == 'pt':  # Portugal
    return 'pt/en/'
  if country == 'ru':  # Russia
    return 'ru/ru/'
  if country == 'se':  # Sweden
    return 'se/sv/'
  if country == 'uk':  # United Kingdom
    return 'uk/en/'
  if country == 'za':  # South Africa
    return 'za/en/'
  if country == 'br':  # Brazil
    return 'br/pt/'
  if country == 'ca':  # Canada
    return 'ca/en/'
  if country == 'mx':  # Mexico
    return 'mx/es/'
  if country == 'us':  # United States
    return 'us/en/'
  if country == 'au':  # Australia
    return 'au/en/'
  if country == 'cn':  # China
    return 'cn/zh/'
  if country == 'in':  # India
    return 'in/en/'
  # default
  return 'en/us/'

def urlised_server_info(vendor, country, server_info):
  #server_inf = server_info
  if vendor == 'dell' :
    # Dell support URLs (idea and tables borrowed from check_openmanage)
    du = 'http://www.dell.com/support/home/' + dell_country(country) + '04/product-support/product/poweredge-'
    if (server_info is not None) :
      p=re.match('(.*)PowerEdge (.*) (.*)',server_info)
      if (p is not None) :
        md=p.group(2)
        if md == 'R210 II':
          md='r210-2'
        md=md.lower()
        server_info = p.group(1) + '<a href="' + du + md + '/">PowerEdge ' + p.group(2)+'</a> ' + p.group(3)
  elif vendor == 'hp':
    return server_info
  elif vendor == 'ibm':
    return server_info
  elif vendor == 'intel':
    return server_info

  return server_info

# ----------------------------------------------------------------------

def system_tag_url(vendor,country):
  if vendor == 'dell':
    # Dell support sites
    supportsite = 'http://www.dell.com/support/home/'
    dellsuffix = '19/product-support/servicetag/'

    # warranty URLs for different country codes
    return supportsite + dell_country(country) + dellsuffix
  # elif vendor == 'hp':
  # elif vendor == 'ibm':
  # elif vendor == 'intel':

  return ''

# ----------------------------------------------------------------------

def urlised_serialnumber(vendor,country,SerialNumber):
  if SerialNumber is not None :
    tu = system_tag_url(vendor,country)
    if tu != '' :
      SerialNumber = '<a href="' + tu + SerialNumber + '">' + SerialNumber + '</a>'
  return SerialNumber

# ----------------------------------------------------------------------

def verboseoutput(message) :
  if verbose:
    print(time.strftime("%Y%m%d %H:%M:%S"), message)

# ----------------------------------------------------------------------

def getopts() :
  global hosturl,hostname,cimport,sslproto,user,password,vendor,verbose,perfdata,urlise_country,timeout,ignore_list,regex,get_power,get_volts,get_current,get_temp,get_fan,get_lcd,get_intrusion
  usage = "usage: %prog -H hostname -U username -P password [-C port -S proto -V vendor -v -p -I XX -i list,list -r]\n" \
    "example: %prog -H hostname -U root -P password -C 5989 -V auto -I uk\n\n" \
    "or, verbosely:\n\n" \
    "usage: %prog --host=hostname --user=username --pass=password [--cimport=port --sslproto=version --vendor=system --verbose --perfdata --html=XX]\n"

  parser = OptionParser(usage=usage, version="%prog "+version)
  group1 = OptionGroup(parser, 'Mandatory parameters')
  group2 = OptionGroup(parser, 'Optional parameters')

  group1.add_option("-H", "--host", dest="host", help="connect to HOST", metavar="HOST")
  group1.add_option("-U", "--user", dest="user", help="user to connect as", metavar="USER")
  group1.add_option("-P", "--pass", dest="password", \
      help="password, if password matches file:<path>, first line of given file will be used as password", metavar="PASS")

  group2.add_option("-C", "--cimport", dest="cimport", help="CIM port (default 5989)", metavar="CIMPORT")
  group2.add_option("-S", "--sslproto", dest="sslproto", help="SSL/TLS protocol version to overwrite system default: SSLv2, SSLv3, TLSv1, TLSv1.1, TLSv1.2, TLSv1.3", metavar="SSLPROTO")
  group2.add_option("-V", "--vendor", dest="vendor", help="Vendor code: auto, dell, hp, ibm, intel, or unknown (default)", \
      metavar="VENDOR", type='choice', choices=['auto','dell','hp','ibm','intel','unknown'],default="unknown")
  group2.add_option("-v", "--verbose", action="store_true", dest="verbose", default=False, \
      help="print status messages to stdout (default is to be quiet)")
  group2.add_option("-p", "--perfdata", action="store_true", dest="perfdata", default=False, \
      help="collect performance data for pnp4nagios (default is not to)")
  group2.add_option("-I", "--html", dest="urlise_country", default="", \
      help="generate html links for country XX (default is not to)", metavar="XX")
  group2.add_option("-t", "--timeout", action="store", type="int", dest="timeout", default=0, \
      help="timeout in seconds - no effect on Windows (default = no timeout)")
  group2.add_option("-i", "--ignore", action="store", type="string", dest="ignore", default="", \
      help="comma-separated list of elements to ignore")
  group2.add_option("-r", "--regex", action="store_true", dest="regex", default=False, \
      help="allow regular expression lookup of ignore list")
  group2.add_option("--no-power", action="store_false", dest="get_power", default=True, \
      help="don't collect power performance data")
  group2.add_option("--no-volts", action="store_false", dest="get_volts", default=True, \
      help="don't collect voltage performance data")
  group2.add_option("--no-current", action="store_false", dest="get_current", default=True, \
      help="don't collect current performance data")
  group2.add_option("--no-temp", action="store_false", dest="get_temp", default=True, \
      help="don't collect temperature performance data")
  group2.add_option("--no-fan", action="store_false", dest="get_fan", default=True, \
      help="don't collect fan performance data")
  group2.add_option("--no-lcd", action="store_false", dest="get_lcd", default=True, \
      help="don't collect lcd/front display status")
  group2.add_option("--no-intrusion", action="store_false", dest="get_intrusion", default=True, \
      help="don't collect chassis intrusion status")

  parser.add_option_group(group1)
  parser.add_option_group(group2)

  # check input arguments
  if len(sys.argv) < 2:
    print("no parameters specified\n")
    parser.print_help()
    sys.exit(-1)
  # if first argument starts with 'https://' we have old-style parameters, so handle in old way
  if re.match("https://",sys.argv[1]):
    # check input arguments
    if len(sys.argv) < 5:
      print("too few parameters\n")
      parser.print_help()
      sys.exit(-1)
    if len(sys.argv) > 5 :
      if sys.argv[5] == "verbose" :
        verbose = True
    hosturl = sys.argv[1]
    user = sys.argv[2]
    password = sys.argv[3]
    vendor = sys.argv[4]
  else:
    # we're dealing with new-style parameters, so go get them!
    (options, args) = parser.parse_args()

    # Making sure all mandatory options appeared.
    mandatories = ['host', 'user', 'password']
    for m in mandatories:
      if not options.__dict__[m]:
        print("mandatory option '" + m + "' not defined. read usage in help.\n")
        parser.print_help()
        sys.exit(-1)

    hostname=options.host.lower()
    # if user has put "https://" in front of hostname out of habit, do the right thing
    # hosturl will end up as https://hostname
    if re.match('^https://',hostname):
      hosturl = hostname
    else:
      hosturl = 'https://' + hostname

    user=options.user
    password=options.password
    cimport=options.cimport
    sslproto=options.sslproto
    vendor=options.vendor.lower()
    verbose=options.verbose
    perfdata=options.perfdata
    urlise_country=options.urlise_country.lower()
    timeout=options.timeout
    ignore_list=options.ignore.split(',')
    regex=options.regex
    get_power=options.get_power
    get_volts=options.get_volts
    get_current=options.get_current
    get_temp=options.get_temp
    get_fan=options.get_fan
    get_lcd=options.get_lcd
    get_intrusion=options.get_intrusion

  # if user or password starts with 'file:', use the first string in file as user, second as password
  if (re.match('^file:', user) or re.match('^file:', password)):
        if re.match('^file:', user):
          filextract = re.sub('^file:', '', user)
          filename = open(filextract, 'r')
          filetext = filename.readline().split()
          user = filetext[0]
          password = filetext[1]
          filename.close()
        elif re.match('^file:', password):
          filextract = re.sub('^file:', '', password)
          filename = open(filextract, 'r')
          filetext = filename.readline().split()
          password = filetext[0]
          filename.close()

# ----------------------------------------------------------------------

getopts()

# if running on Windows, don't use timeouts and signal.alarm
on_windows = True
os_platform = sys.platform
if os_platform != "win32":
  on_windows = False
  import signal
  def handler(signum, frame):
    print('UNKNOWN: Execution time too long!')
    sys.exit(ExitUnknown)

# Use non-default CIM port
if cimport:
  verboseoutput("Using manually defined CIM port "+cimport)
  hosturl += ':'+cimport 

# Use non-default SSL protocol version
if sslproto:
  verboseoutput("Using non-default SSL protocol: "+sslproto)
  allowed_protos = ["SSLv2", "SSLv3", "TLSv1", "TLSv1.1", "TLSv1.2", "TLSv1.3"]
  if any(proto.lower() == sslproto.lower() for proto in allowed_protos):
    import os
    sslconfpath = '/tmp/'+hostname+'_openssl.conf'
    verboseoutput("Creating OpenSSL config file: "+sslconfpath)
    try:
      with open(sslconfpath, 'w') as config_file:
          config_file.write("openssl_conf = openssl_init\n[openssl_init]\nssl_conf = ssl_configuration\n[ssl_configuration]\nsystem_default = tls_system_default\n[tls_system_default]\nMinProtocol = "+sslproto+"\n")
    except Exception as e:
      print('CRITICAL: An error occured while trying to write ssl config file: %s (%s)' % (sslconfpath, e))
      sys.exit(ExitCritical)
    os.environ["OPENSSL_CONF"] = sslconfpath
  else:
    print('CRITICAL: Invalid SSL protocol version given!')
    sys.exit(ExitCritical)

# Append lcd related elements to ignore list if --no-lcd was used
verboseoutput("LCD Status: %s" % get_lcd)
if not get_lcd:
  ignore_list.append("System Board 1 LCD Cable Pres 0: Connected")
  ignore_list.append("System Board 1 VGA Cable Pres 0: Connected")
  ignore_list.append("Front Panel Board 1 FP LCD Cable 0: Connected")
  ignore_list.append("Front Panel Board 1 FP LCD Cable 0: Config Error")

# Append chassis intrusion related elements to ignore list if --no-intrusion was used
verboseoutput("Chassis Intrusion Status: %s" % get_intrusion)
if not get_intrusion:
  ignore_list.append("System Chassis 1 Chassis Intru: General Chassis intrusion")
  ignore_list.append("System Chassis 1 Chassis Intru: Drive Bay intrusion")
  ignore_list.append("System Chassis 1 Chassis Intru: I/O Card area intrusion")
  ignore_list.append("System Chassis 1 Chassis Intru: Processor area intrusion")
  ignore_list.append("System Chassis 1 Chassis Intru: System unplugged from LAN")
  ignore_list.append("System Chassis 1 Chassis Intru: Unauthorized dock")
  ignore_list.append("System Chassis 1 Chassis Intru: FAN area intrusion")
  ignore_list.append("System Chassis 1 Chassis Intru: Unknown")

# connection to host
verboseoutput("Connection to "+hosturl)
# pywbem 0.7.0 handling is special, some patched 0.7.0 installations work differently
try:
  pywbemversion = pywbem.__version__
except:
  pywbemversion = pkg_resources.get_distribution("pywbem").version
else:
  pywbemversion = pywbem.__version__
verboseoutput("Found pywbem version "+pywbemversion)

if '0.7.' in pywbemversion:
  try:
    conntest = pywbem.WBEMConnection(hosturl, (user,password))
    c = conntest.EnumerateInstances('CIM_Card')
  except:
    #raise
    verboseoutput("Connection error, disable SSL certificate verification (probably patched pywbem)")
    wbemclient = pywbem.WBEMConnection(hosturl, (user,password), no_verification=True)
  else:
    verboseoutput("Connection worked")
    wbemclient = pywbem.WBEMConnection(hosturl, (user,password))
# pywbem 0.8.0 and later
else:
  wbemclient = pywbem.WBEMConnection(hosturl, (user,password), NS, no_verification=True)

# Add a timeout for the script. When using with Nagios, the Nagios timeout cannot be < than plugin timeout.
if on_windows == False and timeout > 0:
  signal.signal(signal.SIGALRM, handler)
  signal.alarm(timeout)

# run the check for each defined class
GlobalStatus = ExitUnknown
server_info = ""
bios_info = ""
SerialNumber = ""
ExitMsg = ""

# if vendor is specified as 'auto', try to get vendor from CIM
# note: the default vendor is 'unknown'
if vendor=='auto':
  try:
    c=wbemclient.EnumerateInstances('CIM_Chassis')
  except pywbem.cim_operations.CIMError as args:
    if ( args[1].find('Socket error') >= 0 ):
      print("UNKNOWN: {}".format(args))
      sys.exit (ExitUnknown)
    elif ( args[1].find('ThreadPool --- Failed to enqueue request') >= 0 ):
      print("UNKNOWN: {}".format(args))
      sys.exit (ExitUnknown)
    else:
      verboseoutput("Unknown CIM Error: %s" % args)
  except pywbem._exceptions.ConnectionError as args:
    GlobalStatus = ExitUnknown
    print("UNKNOWN: {}".format(args))
    sys.exit (GlobalStatus)
  except pywbem.cim_http.AuthError as arg:
    verboseoutput("Global exit set to UNKNOWN")
    GlobalStatus = ExitUnknown
    print("UNKNOWN: Authentication Error")
    sys.exit (GlobalStatus)
  else:
    man=c[0][u'Manufacturer']
    if re.match("Dell",man):
      vendor="dell"
    elif re.match("HP",man):
      vendor="hp"
    elif re.match("IBM",man):
      vendor="ibm"
    elif re.match("Intel",man):
      vendor="intel"
    else:
      vendor='unknown'

for classe in ClassesToCheck :
  verboseoutput("Check classe "+classe)
  try:
    instance_list = wbemclient.EnumerateInstances(classe)
  except pywbem.cim_operations.CIMError as args:
    if ( args[1].find('Socket error') >= 0 ):
      print("UNKNOWN: {}".format(args))
      sys.exit (ExitUnknown)
    elif ( args[1].find('ThreadPool --- Failed to enqueue request') >= 0 ):
      print("UNKNOWN: {}".format(args))
      sys.exit (ExitUnknown)
    else:
      verboseoutput("Unknown CIM Error: %s" % args)
  except pywbem._exceptions.ConnectionError as args:
    GlobalStatus = ExitUnknown
    print("UNKNOWN: {}".format(args))
    sys.exit (GlobalStatus)
  except pywbem.cim_http.AuthError as arg:
    verboseoutput("Global exit set to UNKNOWN")
    GlobalStatus = ExitUnknown
    print("UNKNOWN: Authentication Error")
    sys.exit (GlobalStatus)
  else:
    # GlobalStatus = ExitOK #ARR
    for instance in instance_list :
      elementName = instance['ElementName']
      if elementName is None :
        elementName = 'Unknown'
      elementNameValue = elementName
      verboseoutput("  Element Name = "+elementName)

      # Ignore element if we don't want it
      if (regex == True) and (len(ignore_list) > 0) :
        for ignore in ignore_list :
          if re.search(ignore, elementName, re.IGNORECASE) :
            verboseoutput("    (ignored through regex)")
            regex_ignore_list.append(elementName)

      if (elementName in ignore_list) or (elementName in regex_ignore_list) :
        verboseoutput("    (ignored)")
        continue

      # BIOS & Server info
      if elementName == 'System BIOS' :
        bios_info =     instance[u'Name'] + ': ' \
            + instance[u'VersionString'] + ' ' \
            + str(instance[u'ReleaseDate'].datetime.date())
        verboseoutput("    VersionString = "+instance[u'VersionString'])

      elif elementName == 'Chassis' :
        man = instance[u'Manufacturer']
        if man is None :
          man = 'Unknown Manufacturer'
        verboseoutput("    Manufacturer = "+man)
        SerialNumber = instance[u'SerialNumber']
        SerialChassis = instance[u'SerialNumber']
        if SerialNumber:
          verboseoutput("    SerialNumber = "+SerialNumber)
        server_info = man + ' '
        if vendor != 'intel':
          model = instance[u'Model']
          if model:
            verboseoutput("    Model = "+model)
            server_info +=  model + ' s/n:'

      elif elementName == 'Server Blade' :
        SerialNumber = instance[u'SerialNumber']
        if SerialNumber:
          verboseoutput("    SerialNumber = "+SerialNumber)
          isblade = "yes"

      # Report detail of Numeric Sensors and generate nagios perfdata

      if classe == "CIM_NumericSensor" :
        sensorType = instance[u'sensorType']
        sensStr = sensor_Type.get(sensorType,"Unknown")
        if sensorType:
          verboseoutput("    sensorType = %d - %s" % (sensorType,sensStr))
        units = instance[u'BaseUnits']
        if units:
          verboseoutput("    BaseUnits = %d" % units)
        # grab some of these values for Nagios performance data
        scale = 10**instance[u'UnitModifier']
        verboseoutput("    Scaled by = %f " % scale)
        cr = int(instance[u'CurrentReading'])*scale
        verboseoutput("    Current Reading = %f" % cr)
        elementNameValue = "%s: %g" % (elementName,cr)
        ltnc = 0
        utnc = 0
        ltc  = 0
        utc  = 0
        if instance[u'LowerThresholdNonCritical'] is not None:
          ltnc = instance[u'LowerThresholdNonCritical']*scale
          verboseoutput("    Lower Threshold Non Critical = %f" % ltnc)
        if instance[u'UpperThresholdNonCritical'] is not None:
          utnc = instance[u'UpperThresholdNonCritical']*scale
          verboseoutput("    Upper Threshold Non Critical = %f" % utnc)
        if instance[u'LowerThresholdCritical'] is not None:
          ltc = instance[u'LowerThresholdCritical']*scale
          verboseoutput("    Lower Threshold Critical = %f" % ltc)
        if instance[u'UpperThresholdCritical'] is not None:
          utc = instance[u'UpperThresholdCritical']*scale
          verboseoutput("    Upper Threshold Critical = %f" % utc)
        #
        if perfdata:
          perf_el = elementName.replace(' ','_')

          # Power and Current
          if sensorType == 4:               # Current or Power Consumption
            if units == 7:            # Watts
              if get_power:
                data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),1) )
            elif units == 6:          # Current
              if get_current:
                data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),3) )

          # PSU Voltage
          elif sensorType == 3:               # Voltage
            if get_volts:
              data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),2) )

          # Temperatures
          elif sensorType == 2:               # Temperature
            if get_temp:
              data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),4) )

          # Fan speeds
          elif sensorType == 5:               # Tachometer
            if get_fan:
              if units == 65:           # percentage
                data.append( ("%s=%g%%;%g;%g " % (perf_el, cr, utnc, utc),6) )
              else:
                data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),5) )

      elif classe == "CIM_Processor" :
        verboseoutput("    Family = %d" % instance['Family'])
        verboseoutput("    CurrentClockSpeed = %dMHz" % instance['CurrentClockSpeed'])

      # HP Check
      if vendor == "hp" :
        if instance['HealthState'] is not None :
          elementStatus = instance['HealthState']
          verboseoutput("    Element HealthState = %d" % elementStatus)
          interpretStatus = {
            0  : ExitOK,    # Unknown
            5  : ExitOK,    # OK
            10 : ExitWarning,  # Degraded
            15 : ExitWarning,  # Minor
            20 : ExitCritical,  # Major
            25 : ExitCritical,  # Critical
            30 : ExitCritical,  # Non-recoverable Error
          }[elementStatus]
          if (interpretStatus == ExitCritical) :
            verboseoutput("Global exit set to CRITICAL")
            GlobalStatus = ExitCritical
            ExitMsg += " CRITICAL : %s " % elementNameValue
          if (interpretStatus == ExitWarning and GlobalStatus != ExitCritical) :
            verboseoutput("Global exit set to WARNING")
            GlobalStatus = ExitWarning
            ExitMsg += " WARNING : %s " % elementNameValue
          # Added the following for when GlobalStatus is ExitCritical and a warning is detected
          # This way the ExitMsg gets added but GlobalStatus isn't changed
          if (interpretStatus == ExitWarning and GlobalStatus == ExitCritical) : # ARR
            ExitMsg += " WARNING : %s " % elementNameValue #ARR
          # Added the following so that GlobalStatus gets set to OK if there's no warning or critical
          if (interpretStatus == ExitOK and GlobalStatus != ExitWarning and GlobalStatus != ExitCritical) : #ARR
            GlobalStatus = ExitOK #ARR



      # Dell, Intel, IBM and unknown hardware check
      elif (vendor == "dell" or vendor == "intel" or vendor == "ibm" or vendor=="unknown") :
        # Added 20121027 As long as Dell doesnt correct these CIM elements return code we have to ignore it
        ignore_list.append("System Board 1 Riser Config Err 0: Connected")
        ignore_list.append("Add-in Card 4 PEM Presence 0: Connected")
        if instance['OperationalStatus'] is not None :
          elementStatus = instance['OperationalStatus'][0]
          verboseoutput("    Element Op Status = %d" % elementStatus)
          interpretStatus = {
            0  : ExitOK,            # Unknown
            1  : ExitCritical,      # Other
            2  : ExitOK,            # OK
            3  : ExitWarning,       # Degraded
            4  : ExitWarning,       # Stressed
            5  : ExitWarning,       # Predictive Failure
            6  : ExitCritical,      # Error
            7  : ExitCritical,      # Non-Recoverable Error
            8  : ExitWarning,       # Starting
            9  : ExitWarning,       # Stopping
            10 : ExitCritical,      # Stopped
            11 : ExitOK,            # In Service
            12 : ExitWarning,       # No Contact
            13 : ExitCritical,      # Lost Communication
            14 : ExitCritical,      # Aborted
            15 : ExitOK,            # Dormant
            16 : ExitCritical,      # Supporting Entity in Error
            17 : ExitOK,            # Completed
            18 : ExitOK,            # Power Mode
            19 : ExitOK,            # DMTF Reserved
            20 : ExitOK             # Vendor Reserved
          }[elementStatus]
          if (interpretStatus == ExitCritical) :
            verboseoutput("Global exit set to CRITICAL")
            GlobalStatus = ExitCritical
            ExitMsg += " CRITICAL : %s " % elementNameValue
          if (interpretStatus == ExitWarning and GlobalStatus != ExitCritical) :
            verboseoutput("Global exit set to WARNING")
            GlobalStatus = ExitWarning
            ExitMsg += " WARNING : %s " % elementNameValue
          # Added same logic as in 20100702 here, otherwise Dell servers would return UNKNOWN instead of OK
          if (interpretStatus == ExitWarning and GlobalStatus == ExitCritical) : # ARR
            ExitMsg += " WARNING : %s " % elementNameValue #ARR
          if (interpretStatus == ExitOK and GlobalStatus != ExitWarning and GlobalStatus != ExitCritical) : #ARR
            GlobalStatus = ExitOK #ARR
        if elementName == 'Server Blade' :
                if SerialNumber :
                        if SerialNumber.find(".") != -1 :
                                SerialNumber = SerialNumber.split('.')[1]


# Munge the ouptput to give links to documentation and warranty info
if (urlise_country != '') :
  SerialNumber = urlised_serialnumber(vendor,urlise_country,SerialNumber)
  server_info = urlised_server_info(vendor,urlise_country,server_info)

# If this is a blade server, also output chassis serial number as additional info
if (isblade == "yes") :
  SerialNumber += " Chassis S/N: %s " % (SerialChassis)

# Output performance data
perf = '|'
if perfdata:
  sdata=[]
  ctr=[0,0,0,0,0,0,0]
  # sort the data so we always get perfdata in the right order
  # we make no assumptions about the order in which CIM returns data
  # first sort by element name (effectively) and insert sequence numbers
  for p in sorted(data):
    p1 = p[1]
    sdata.append( ("P%d%s_%d_%s") % (p1,perf_Prefix[p1], ctr[p1], p[0]) )
    ctr[p1] += 1
  # then sort perfdata into groups and output perfdata string
  for p in sorted(sdata):
    perf += p

# sanitise perfdata - don't output "|" if nothing to report
if perf == '|':
  perf = ''

# Cleanup temporary openssl config
if sslproto:
  os.remove(sslconfpath)

if GlobalStatus == ExitOK :
  print("OK - Server: %s %s %s%s" % (server_info, SerialNumber, bios_info, perf))

elif GlobalStatus == ExitUnknown :
  print("UNKNOWN: %s" % (ExitMsg)) #ARR

else:
  print("%s - Server:  %s %s %s%s" % (ExitMsg, server_info, SerialNumber, bios_info, perf))

sys.exit (GlobalStatus)