-- Copyright (c) 2004-2015 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: Port Extender (PEX) information MIB
-- Reference:
-- Version: V1.2
-- History:
--   V1.0 2012-11-12 Initial version by Yang Fan
--   V1.1 2014-03-31 Changed MIB node name to PEX by zushuzhi
--   V1.2 2015-10-15 Added hh3cPexDeviceInfoTable and hh3cPexTopoTable
--                   by zushuzhi
-- ============================================================================
HH3C-PEX-MIB DEFINITIONS ::= BEGIN
IMPORTS
    hh3cCommon
        FROM HH3C-OID-MIB
    entPhysicalIndex, entPhysicalDescr
        FROM ENTITY-MIB
    Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
        FROM SNMPv2-SMI
    RowStatus, DisplayString
        FROM SNMPv2-TC;

hh3cPex MODULE-IDENTITY
    LAST-UPDATED "201510151129Z"        -- 15th October, 2015 at 11:29 GMT
    ORGANIZATION
        "New H3C Technologies Co., Ltd."
    CONTACT-INFO
        "Platform Team New H3C Technologies Co., Ltd.
         Haidian District Beijing P.R. China
         Http://www.h3c.com
         Zip:100085"
    DESCRIPTION
        "This MIB is used to manage Port Extender (PEX)
         information.  This MIB is applicable to products that support PEX."
    REVISION "201510151129Z"
    DESCRIPTION
        "Added hh3cPexDeviceInfoTable and hh3cPexTopoTable."
    REVISION "201211121129Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { hh3cCommon 129 }

-- PEX Specification Information

hh3cPexSpecInfo OBJECT IDENTIFIER ::= { hh3cPex 1 }

hh3cPexPortMinId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Lowest PEX port ID that can be used to uniquely identify a PEX port."
    ::= { hh3cPexSpecInfo 1 }

hh3cPexPortMaxId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highest PEX port ID that can be used to uniquely identify a PEX port."
    ::= { hh3cPexSpecInfo 2 }

hh3cPexMinAssociateId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Lowest ID that can be assigned to a port extender (PEX)."
    ::= { hh3cPexSpecInfo 3 }

hh3cPexMaxAssociateId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highest ID that can be assigned to a PEX."
    ::= { hh3cPexSpecInfo 4 }

hh3cPexMaxPortPerPexPort OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Maximum number of ports that can be bound to a PEX port."
    ::= { hh3cPexSpecInfo 5 }

-- PEX Information

hh3cPexTable OBJECT IDENTIFIER ::= { hh3cPex 2 }

hh3cPexPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hh3cPexPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains objects used to configure the PEX ports."
    ::= { hh3cPexTable 1 }

hh3cPexPortEntry OBJECT-TYPE
    SYNTAX      Hh3cPexPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a PEX."
    INDEX
        {
            hh3cPexPortId
        }
    ::= { hh3cPexPortTable 1 }

Hh3cPexPortEntry ::= SEQUENCE
    {
        hh3cPexPortId               Integer32,
        hh3cPexPortAssociateId      Integer32,
        hh3cPexPortEntPhysicalIndex Integer32,
        hh3cPexPortDescr            DisplayString,
        hh3cPexPortStatus           INTEGER,
        hh3cPexPortRowStatus        RowStatus
    }

hh3cPexPortId OBJECT-TYPE
    SYNTAX      Integer32(1..2147483647)
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "ID that can be used to uniquely identify a PEX port.  The value range
        is hh3cPexPortMinId to hh3cPexPortMaxId."
    ::= { hh3cPexPortEntry 1 }

hh3cPexPortAssociateId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "ID assigned to a PEX.  The
        value range is hh3cPexMinAssociateId to hh3cPexMaxAssociateId.
        The value is 0xffff if the PEX is not assigned an ID.
        For a successful configuration, the ID should not be used by any
        other PEX."
    DEFVAL { 65535 }
    ::= { hh3cPexPortEntry 2 }

hh3cPexPortEntPhysicalIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Entity index of a PEX in the IRF.  A value of zero
         indicates that the PEX is not online."
    DEFVAL { 0 }
    ::= { hh3cPexPortEntry 3 }

hh3cPexPortDescr OBJECT-TYPE
    SYNTAX      DisplayString(SIZE(0..79))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Description for the PEX port.  The default value is
        'pex-port XXXX', where 'XXXX' is hh3cPexPortId.
        Writing a zero-length string to this object resets the value to the
        default."
    ::= { hh3cPexPortEntry 4 }

hh3cPexPortStatus OBJECT-TYPE
    SYNTAX      INTEGER
        {
            offline(1),
            loading(2),
            online(3)
        }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the PEX.
        offline: The PEX is absent or its configuration is incomplete.
        loading: The PEX is loading software.
        online: The PEX is operating correctly."
    DEFVAL { offline }
    ::= { hh3cPexPortEntry 5 }

hh3cPexPortRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The control that allows creation and deletion of entries.
        Values include createAndGo, active, and destroy.
        If the row to be created or modified already exists,
        an error message is returned.  If the row to be deleted does not exist,
        a success message is returned."
    ::= { hh3cPexPortEntry 6 }


-- PEX PhyPort Information

hh3cPexPhyPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hh3cPexPhyPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains objects used to manage physical ports
        that can be bound or are already bound to a PEX port."
    ::= { hh3cPexTable 2 }

hh3cPexPhyPortEntry OBJECT-TYPE
    SYNTAX      Hh3cPexPhyPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a physical port that can be bound to or
        has been bound to a PEX port."
    INDEX
        {
            entPhysicalIndex
        }
    ::= { hh3cPexPhyPortTable 1 }

Hh3cPexPhyPortEntry ::= SEQUENCE
    {
        hh3cPexPhyPortStatus           INTEGER,
        hh3cPexPhyPortBelongToPexPort  Integer32,
        hh3cPexPhyPortNeighborEntIndex Integer32
    }

hh3cPexPhyPortStatus OBJECT-TYPE
    SYNTAX      INTEGER
        {
            unknown(1),
            down(2),
            blocked(3),
            forwarding(4)
        }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the physical port that is bound to a PEX port.
        The following are status values:
        unknown: The physical port is not bound to any PEX port.
        down: The physical port is link down.
        blocked: The physical port is blocked and cannot forward traffic.
        forwarding: The physical port can forwarding traffic."
    DEFVAL { unknown }
    ::= { hh3cPexPhyPortEntry 1 }

hh3cPexPhyPortBelongToPexPort OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "ID of the PEX port to which the physical port belongs.  The value
        range is hh3cPexPortMinId to hh3cPexPortMaxId.  A value of zero
        indicates that the port doesn't belong to any PEX port."
    DEFVAL { 0 }
    ::= { hh3cPexPhyPortEntry 2 }

hh3cPexPhyPortNeighborEntIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Entity index of a physical port that connects the PEX to the parent
        device.  This value is identical to entPhysicalIndex in ENTITY-MIB.
        A value of zero indicates that the physical port is not bound to any
        PEX port or is not up."
    ::= { hh3cPexPhyPortEntry 3 }

-- PEX Topology Information
hh3cPexDeviceInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hh3cPexDeviceInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains online PEXs in the IRF system."
    ::= { hh3cPexTable 3 }

hh3cPexDeviceInfoEntry OBJECT-TYPE
    SYNTAX      Hh3cPexDeviceInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a PEX in the IRF system.  The index is the PEX
        entity index."
    INDEX
        {
            entPhysicalIndex
        }
    ::= { hh3cPexDeviceInfoTable 1 }

Hh3cPexDeviceInfoEntry ::= SEQUENCE
    {
        hh3cPexDeviceStatus           INTEGER,
        hh3cPexDeviceAssociateId      Integer32
    }

hh3cPexDeviceStatus OBJECT-TYPE
    SYNTAX      INTEGER
        {
            normal(1),
            faulty(2)
        }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the PEX.
        normal: The PEX is operating correctly.
        faulty: The PEX is faulty."
    ::= { hh3cPexDeviceInfoEntry 1 }

hh3cPexDeviceAssociateId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ID assigned to the PEX."
    ::= { hh3cPexDeviceInfoEntry 2 }

hh3cPexTopoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hh3cPexTopoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains information about the PEX physical ports and
        neighbor ports on PEXs."
    ::= { hh3cPexTable 4 }

hh3cPexTopoEntry OBJECT-TYPE
    SYNTAX      Hh3cPexTopoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a PEX link."
    INDEX
        {
            entPhysicalIndex
        }
    ::= { hh3cPexTopoTable 1 }

Hh3cPexTopoEntry ::= SEQUENCE
    {
        hh3cPexNeighborEntIndex Integer32
    }

hh3cPexNeighborEntIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Entity index of a PEX in the IRF system."
    ::= { hh3cPexTopoEntry 1 }

-- PEX Traps

hh3cPexTraps OBJECT IDENTIFIER ::= { hh3cPex 3 }

hh3cPexTrapPrefix OBJECT IDENTIFIER ::= { hh3cPexTraps 0 }

hh3cPexPortOnline  NOTIFICATION-TYPE
    OBJECTS
        {
            hh3cPexPortId,
            hh3cPexPortDescr
        }
    STATUS      current
    DESCRIPTION
        "An hh3cPexPortOnline trap is sent when the PEX transitions to
        online state."
    ::= { hh3cPexTrapPrefix 1 }

hh3cPexPortOffline  NOTIFICATION-TYPE
    OBJECTS
        {
            hh3cPexPortId,
            hh3cPexPortDescr
        }
    STATUS      current
    DESCRIPTION
        "An hh3cPexPortOnline trap is sent when the PEX transitions to
        offline state."
    ::= { hh3cPexTrapPrefix 2 }

hh3cPexPhyPortForwarding  NOTIFICATION-TYPE
    OBJECTS
        {
            hh3cPexEntPhysicalIndexBind,
            entPhysicalDescr
        }
    STATUS      current
    DESCRIPTION
        "An hh3cPexPhyPortForwarding trap is sent when the PEX physical port
        transitions to forwarding state."
    ::= { hh3cPexTrapPrefix 3 }

hh3cPexPhyPortBlocked  NOTIFICATION-TYPE
    OBJECTS
        {
            hh3cPexEntPhysicalIndexBind,
            entPhysicalDescr
        }
    STATUS      current
    DESCRIPTION
        "An hh3cPexPhyPortBlocked trap is sent when the PEX physical port
        transitions from forwarding state to blocked state."
    ::= { hh3cPexTrapPrefix 4 }

hh3cPexTrapObjects OBJECT IDENTIFIER ::= { hh3cPex 4 }

hh3cPexEntPhysicalIndexBind OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS accessible-for-notify
    STATUS     current
    DESCRIPTION
        "This index is identical to entPhysicalIndex in ENTITY-MIB."
    ::= { hh3cPexTrapObjects 1 }
END