-- This file was included in WWP MIB release 04-16-00-0047
 --
 -- CIENA-CES-ALARM-MIB.my
 --

 CIENA-CES-ALARM-MIB DEFINITIONS ::= BEGIN

 IMPORTS
     Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY
            FROM SNMPv2-SMI
     TruthValue, DisplayString
            FROM SNMPv2-TC
     ItuPerceivedSeverity
            FROM ITU-ALARM-TC-MIB
     alarmListName, alarmModelIndex, alarmActiveDateAndTime, alarmActiveIndex, alarmClearIndex, alarmClearDateAndTime, alarmModelState
            FROM ALARM-MIB
     cienaCesConfig
            FROM CIENA-SMI;

 cienaCesAlarmMIB MODULE-IDENTITY
        LAST-UPDATED "201611070000Z"
        ORGANIZATION "Ciena, Inc"
        CONTACT-INFO
            "   Mib Meister
                115 North Sullivan Road
                Spokane Valley, WA 99037
                USA
                Phone:  +1 509 242 9000
                Email:  support@ciena.com"
        DESCRIPTION
            "This module defines the alarm objects."

        REVISION "201611070000Z"
        DESCRIPTION
            "Added cienaCesAlarmActiveTimeStamp to the cienaCesAlarmActiveTable."

        REVISION "201602220000Z"
        DESCRIPTION
            "Added cienaCesAlarmSense to the cienaCesAlarmEntry object
             Added cienaCesAlarmTrigger to the cienaCesAlarmEntry object."

        REVISION "201509160000Z"
        DESCRIPTION
            "Added cienaCesAlarmLogModelIndex and cienaCesAlarmLogTimeStamp to the cienaCesAlarmLogEntry object"
        
        REVISION "201505130000Z"
        DESCRIPTION
            "Change MAX-ACCESS of cienaCesAlarmCutoff from 'read-only' to 'read-write'."

        REVISION "201203140130Z"
        DESCRIPTION
            "Initial creation."
        ::= { cienaCesConfig 24 }

 --
 -- Node definitions
 --

 cienaCesAlarmMIBObjects     OBJECT IDENTIFIER ::= { cienaCesAlarmMIB 1 }

 cienaCesAlarmGlobal         OBJECT IDENTIFIER ::= { cienaCesAlarmMIBObjects 1 }
 cienaCesAlarm               OBJECT IDENTIFIER ::= { cienaCesAlarmMIBObjects 2 }
 cienaCesAlarmActive         OBJECT IDENTIFIER ::= { cienaCesAlarmMIBObjects 3 }
 cienaCesAlarmClear          OBJECT IDENTIFIER ::= { cienaCesAlarmMIBObjects 4 }
 cienaCesAlarmLog            OBJECT IDENTIFIER ::= { cienaCesAlarmMIBObjects 5 }

 --  Notifications

 cienaCesAlarmMIBNotificationPrefix  OBJECT IDENTIFIER ::= { cienaCesAlarmMIB 2 }
 cienaCesAlarmMIBNotifications       OBJECT IDENTIFIER ::= { cienaCesAlarmMIBNotificationPrefix 0 }

 -- Conformance information

 cienaCesAlarmMIBConformance OBJECT IDENTIFIER ::= { cienaCesAlarmMIB 3 }
 cienaCesAlarmMIBCompliances OBJECT IDENTIFIER ::= { cienaCesAlarmMIBConformance 1 }
 cienaCesAlarmMIBGroups      OBJECT IDENTIFIER ::= { cienaCesAlarmMIBConformance 2 }

 --
 -- Global stuff
 --
 cienaCesAlarmCutOff    OBJECT-TYPE
     SYNTAX            TruthValue
     MAX-ACCESS        read-write
     STATUS            current
     DESCRIPTION
         "When read this object will always return false.
          When written with a value of true, will invoke the alarm cutoff."
     ::= { cienaCesAlarmGlobal 1 }

 --
 -- Alarm table
 --
 cienaCesAlarmTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF CienaCesAlarmEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of alarm entries supported by device."
     ::= { cienaCesAlarm 1 }

 cienaCesAlarmEntry     OBJECT-TYPE
     SYNTAX         CienaCesAlarmEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the alarm table."
     INDEX  { alarmListName, alarmModelIndex, alarmModelState  }
     ::= { cienaCesAlarmTable 1 }

 CienaCesAlarmEntry ::=  SEQUENCE  {
     cienaCesAlarmDescription                           DisplayString,
     cienaCesAlarmThreshold                             Integer32,
     cienaCesAlarmLeak                                  Integer32,
     cienaCesAlarmGPO                                   TruthValue,
     cienaCesAlarmEvery                                 Integer32,
     cienaCesAlarmToMinor                               Integer32,
     cienaCesAlarmToMajor                               Integer32,
     cienaCesAlarmToCritical                            Integer32,
     cienaCesAlarmSense                                 TruthValue,
     cienaCesAlarmTrigger                               TruthValue
 }

 cienaCesAlarmDescription  OBJECT-TYPE
     SYNTAX            DisplayString
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the description of the alarm."
     ::= { cienaCesAlarmEntry 1 }

 cienaCesAlarmThreshold  OBJECT-TYPE
     SYNTAX            Integer32 (1..65535)
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the threshold for the alarm."
     ::= { cienaCesAlarmEntry 2 }

 cienaCesAlarmLeak  OBJECT-TYPE
     SYNTAX            Integer32 (0..65535)
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the alarm leak for the given alarm."
     ::= { cienaCesAlarmEntry 3 }

 cienaCesAlarmGPO  OBJECT-TYPE
     SYNTAX            TruthValue
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the GPO detection for this alarm."
     ::= { cienaCesAlarmEntry 4 }

 cienaCesAlarmEvery  OBJECT-TYPE
     SYNTAX            Integer32
     UNITS             "seconds"
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmEntry 5 }

 cienaCesAlarmToMinor  OBJECT-TYPE
     SYNTAX            Integer32
     UNITS             "seconds"
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the time after which the severity specified by alarmModelState
              will be escalated to minor."
     ::= { cienaCesAlarmEntry 6 }

 cienaCesAlarmToMajor  OBJECT-TYPE
     SYNTAX            Integer32
     UNITS             "seconds"
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the time after which the severity specified by alarmModelState
              will be escalated to major."
     ::= { cienaCesAlarmEntry 7 }

 cienaCesAlarmToCritical  OBJECT-TYPE
     SYNTAX            Integer32
     UNITS             "seconds"
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the time after which the severity specified by alarmModelState
              will be escalated to critical."
     ::= { cienaCesAlarmEntry 8 }

 cienaCesAlarmSense  OBJECT-TYPE
     SYNTAX          TruthValue
     MAX-ACCESS      read-only
     STATUS          current
     DESCRIPTION
               "This object indicates the polarity of an external alarm input pin.
                This object shall return false(2) for regular (non-external) alarms."
     ::= { cienaCesAlarmEntry 9 }

 cienaCesAlarmTrigger  OBJECT-TYPE
     SYNTAX          TruthValue
     MAX-ACCESS      read-only
     STATUS          current
     DESCRIPTION
               "This object indicates whether an external alarm is
                currently in 'forced' mode. This object shall return
                false(2) for regular (non-external) alarms."
     ::= { cienaCesAlarmEntry 10 }

 --
 -- Alarm Severity table
 --
 cienaCesAlarmSeverityTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF CienaCesAlarmSeverityEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of alarm severity entries supported by device."
     ::= { cienaCesAlarm 2 }

 cienaCesAlarmSeverityEntry     OBJECT-TYPE
     SYNTAX         CienaCesAlarmSeverityEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the alarm severity table."
     INDEX  { alarmListName, alarmModelIndex }
     ::= { cienaCesAlarmSeverityTable 1 }

 CienaCesAlarmSeverityEntry ::=  SEQUENCE  {
     cienaCesAlarmSeverity              ItuPerceivedSeverity
 }

 cienaCesAlarmSeverity  OBJECT-TYPE
     SYNTAX            ItuPerceivedSeverity
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object allows changing the severity of the alarm."
     ::= { cienaCesAlarmSeverityEntry 1 }

 --
 -- Active alarm table
 --
 cienaCesAlarmActiveTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF CienaCesAlarmActiveEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of Active supply entries."
     ::= { cienaCesAlarmActive 1 }

 cienaCesAlarmActiveEntry     OBJECT-TYPE
     SYNTAX         CienaCesAlarmActiveEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the Active table providing objects for a
             power supply."
     INDEX  { alarmListName, alarmActiveIndex, alarmActiveDateAndTime }
     ::= { cienaCesAlarmActiveTable 1 }

 CienaCesAlarmActiveEntry ::=  SEQUENCE  {
     cienaCesAlarmActiveSeverity                            ItuPerceivedSeverity,
     cienaCesAlarmActiveInvokeId                            Integer32,
     cienaCesAlarmActiveManagedObjectClass                  INTEGER,
     cienaCesAlarmActiveManagedObjectInterpret              OCTET STRING,
     cienaCesAlarmActiveManagedObjectInstance               OCTET STRING,
     cienaCesAlarmActiveAck                                 TruthValue,
     cienaCesAlarmActiveDescription                         DisplayString,
     cienaCesAlarmActiveTimeStamp                           DisplayString
 }

 cienaCesAlarmActiveSeverity  OBJECT-TYPE
     SYNTAX            ItuPerceivedSeverity
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmActiveEntry 1 }

 cienaCesAlarmActiveInvokeId  OBJECT-TYPE
     SYNTAX            Integer32
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmActiveEntry 2 }

 cienaCesAlarmActiveManagedObjectClass  OBJECT-TYPE
     SYNTAX            INTEGER  {
                        unknown(1),
                        chassis(2),
                        slot(3),
                        port(4)
                        }
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmActiveEntry 3 }

 cienaCesAlarmActiveManagedObjectInterpret  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..15))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates how to interpret cienaCesAlarmActiveManagedObjectInstance."
     ::= { cienaCesAlarmActiveEntry 4 }

 cienaCesAlarmActiveManagedObjectInstance  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..8))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmActiveEntry 5 }

 cienaCesAlarmActiveAck   OBJECT-TYPE
     SYNTAX            TruthValue
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates whether this alarm is acknowledged or not."
     ::= { cienaCesAlarmActiveEntry 6 }

 cienaCesAlarmActiveDescription  OBJECT-TYPE
     SYNTAX            DisplayString
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the description of the alarm."
     ::= { cienaCesAlarmActiveEntry 7 }

 cienaCesAlarmActiveTimeStamp  OBJECT-TYPE
     SYNTAX            DisplayString
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the UTC timestamp for the alarm."
     ::= { cienaCesAlarmActiveEntry 8 }

 --
 -- Clear alarm table
 --
 cienaCesAlarmClearTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF CienaCesAlarmClearEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of Clear supply entries."
     ::= { cienaCesAlarmClear 1 }

 cienaCesAlarmClearEntry     OBJECT-TYPE
     SYNTAX         CienaCesAlarmClearEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the Clear table providing objects for a
             power supply."
     INDEX  { alarmListName, alarmClearIndex, alarmClearDateAndTime }
     ::= { cienaCesAlarmClearTable 1 }

 CienaCesAlarmClearEntry ::=  SEQUENCE  {
     cienaCesAlarmClearManagedObjectClass           INTEGER,
     cienaCesAlarmClearManagedObjectInterpret       OCTET STRING,
     cienaCesAlarmClearManagedObjectInstance        OCTET STRING
 }

 cienaCesAlarmClearManagedObjectClass  OBJECT-TYPE
     SYNTAX            INTEGER  {
                        unknown(1),
                        chassis(2),
                        slot(3),
                        port(4)
                        }
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmClearEntry 3 }

 cienaCesAlarmClearManagedObjectInterpret  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..15))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates how to interpret cienaCesAlarmClearManagedObjectInstance."
     ::= { cienaCesAlarmClearEntry 4 }

 cienaCesAlarmClearManagedObjectInstance  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..6))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmClearEntry 5 }

 --
 -- log alarm table
 --
 cienaCesAlarmLogTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF CienaCesAlarmLogEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of Log supply entries."
     ::= { cienaCesAlarmLog 1 }

 cienaCesAlarmLogEntry     OBJECT-TYPE
     SYNTAX         CienaCesAlarmLogEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the Log table providing objects for a
             power supply."
     INDEX  { alarmListName, cienaCesAlarmLogIndex }
     ::= { cienaCesAlarmLogTable 1 }

 CienaCesAlarmLogEntry ::=  SEQUENCE  {
     cienaCesAlarmLogIndex                      Unsigned32,
     cienaCesAlarmLogSeverity                   ItuPerceivedSeverity,
     cienaCesAlarmLogManagedObjectClass         INTEGER,
     cienaCesAlarmLogManagedObjectInterpret     OCTET STRING,
     cienaCesAlarmLogManagedObjectInstance      OCTET STRING,
     cienaCesAlarmLogModelIndex                 Unsigned32,
     cienaCesAlarmLogTimeStamp                  DisplayString
 }

 cienaCesAlarmLogIndex  OBJECT-TYPE
     SYNTAX            Unsigned32 (1..4294967295)
     MAX-ACCESS        not-accessible
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmLogEntry 1 }

 cienaCesAlarmLogSeverity  OBJECT-TYPE
     SYNTAX            ItuPerceivedSeverity
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmLogEntry 2 }

 cienaCesAlarmLogManagedObjectClass  OBJECT-TYPE
     SYNTAX            INTEGER  {
                        unknown(1),
                        chassis(2),
                        slot(3),
                        port(4)
                        }
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmLogEntry 3 }

 cienaCesAlarmLogManagedObjectInterpret  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..15))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates how to interpret cienaCesAlarmLogManagedObjectInstance."
     ::= { cienaCesAlarmLogEntry 4 }

 cienaCesAlarmLogManagedObjectInstance  OBJECT-TYPE
     SYNTAX            OCTET STRING (SIZE(1..6))
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the unique index of the table."
     ::= { cienaCesAlarmLogEntry 5 }

 cienaCesAlarmLogModelIndex  OBJECT-TYPE
     SYNTAX            Unsigned32 (1..4294967295)
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the corresponding value of the
              alarmModelIndex for this table entry."
     ::= { cienaCesAlarmLogEntry 6 }

 cienaCesAlarmLogTimeStamp  OBJECT-TYPE
     SYNTAX            DisplayString
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "This object indicates the timestamp for the alarm."
     ::= { cienaCesAlarmLogEntry 7 }

 END