-- UBQS-ENVMON-MIB:  Ubiquoss Environmental Monitor MIB file
--
-- June 2009 by Hyung Eun Park          
--
-- Copyright (c) 2009 by Ubiquoss, Corp.
-- All rights reserved.    
-- *****************************************************************
--       

UBQS-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
        Gauge32,
        Integer32
                FROM SNMPv2-SMI
        TEXTUAL-CONVENTION,
        DisplayString,
        TruthValue
                FROM SNMPv2-TC
        MODULE-COMPLIANCE,
        OBJECT-GROUP,
        NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        ubiMgmtv2
                FROM UBQS-SMI;


ubiEnvMonMIB MODULE-IDENTITY
        LAST-UPDATED    "200906250000Z"
        ORGANIZATION    "Ubiquoss Corp."
        CONTACT-INFO
		"	Ubiquoss
			Customer Service

		 Postal: 24F Milennium B/D,
		 	467-12, Dogok-Dong,
			GangNam-Gu, Seoul 135-270
			Korea

		   Tel: 82-2-2190-3100"          
		DESCRIPTION
        "The UBQS-ENVMON-MIB is used for getting 
        the environment information of the system."
        ::= { ubiMgmtv2 2 }
               
     
-- *****************************************************************
-- Type Convention
-- *****************************************************************
UbiEnvMonState ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Represents the state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.

                 warning(2):        the environment is bad, such as temperature
                                    above normal operation range but not too
                                    high.

                 critical(3):       the environment is very bad, such as
                                    temperature much higher than normal
                                    operation limit.

                 shutdown(4):       the environment is the worst, the system
                                    should be shutdown immediately.

                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.

                 notFunctioning(6): the environmental monitor does not 
                                    function properly.
                "
        SYNTAX  INTEGER {
                        normal(1),
                        warning(2),
                        critical(3),
                        shutdown(4),
                        notPresent(5),
                        notFunctioning(6)
                }

-- *****************************************************************
-- ubiEnvMonMIB
-- *****************************************************************

ubiEnvMonObjects 				OBJECT IDENTIFIER ::= { ubiEnvMonMIB 1 }
ubiEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ubiEnvMonMIB 2 }
ubiEnvMonMIBNotificationPrefix 	OBJECT IDENTIFIER ::= { ubiEnvMonMIB 3 } 
ubiEnvMonMIBConformance 		OBJECT IDENTIFIER ::= { ubiEnvMonMIB 4 }

                   
                   
-- *****************************************************************
-- ubiEnvMonTemperatureTable
-- *****************************************************************

	ubiEnvMonTemperatureTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbiEnvMonTemperatureEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of ambient temperature status maintained by the
                environmental monitor."
        ::= { ubiEnvMonObjects 1 }

	ubiEnvMonTemperatureEntry OBJECT-TYPE
        SYNTAX     UbiEnvMonTemperatureEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the ambient temperature status table, representing
                the status of the associated testpoint maintained by the
                environmental monitor."
        INDEX      { ubiEnvMonTemperatureIndex }
        ::= { ubiEnvMonTemperatureTable 1 }

	UbiEnvMonTemperatureEntry ::=
        SEQUENCE {
                ubiEnvMonTemperatureIndex       		Integer32,
                ubiEnvMonTemperatureDescr       		DisplayString,
                ubiEnvMonTemperatureValue       		Gauge32,
                ubiEnvMonTemperatureHighThreshold     	Integer32,       
                ubiEnvMonTemperatureLowThreshold      	Integer32,
         --       ubiEnvMonTemperatureLastShutdown    	Integer32,
                ubiEnvMonTemperatureState             	UbiEnvMonState
        }


	ubiEnvMonTemperatureIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the testpoint being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ubiEnvMonTemperatureEntry 1 }

	ubiEnvMonTemperatureDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..255))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the testpoint 
                 being instrumented."
        ::= { ubiEnvMonTemperatureEntry 2 }

	ubiEnvMonTemperatureValue OBJECT-TYPE
        SYNTAX     Gauge32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current measurement of the testpoint 
                 being instrumented."
        ::= { ubiEnvMonTemperatureEntry 3 }

	ubiEnvMonTemperatureHighThreshold OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-write
        STATUS     current
        DESCRIPTION
                "A high threshold for the temperature. 
                 If a particular value isn't set, this object 
                 displays the default value."
        ::= { ubiEnvMonTemperatureEntry 4 }
   
	ubiEnvMonTemperatureLowThreshold OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-write
        STATUS     current
        DESCRIPTION
                "A low threshold for the temperature.
                If a particular value isn't set, this object 
                displays the default value."
        ::= { ubiEnvMonTemperatureEntry 5 }
   
--	ubiEnvMonTemperatureLastShutdown OBJECT-TYPE
 --       SYNTAX     Integer32
 --       UNITS      "degrees Celsius"
 --      MAX-ACCESS read-only
 --       STATUS     current
 --       DESCRIPTION
 --               "The value of the associated instance of the object
 --               ubiEnvMonTemperatureStatusValue at the time an emergency
 --               shutdown of the managed device was last initiated. "
 --       ::= { ubiEnvMonTemperatureEntry 5 }

	ubiEnvMonTemperatureState OBJECT-TYPE
        SYNTAX     UbiEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the testpoint being instrumented.              
                 Represents the temperature state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.

                 warning(2):        the environment is bad, such as temperature
                                    above normal operation range but not too
                                    high.

                 critical(3):       the environment is very bad, such as
                                    temperature much higher than normal
                                    operation limit.

                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.
               "
        ::= { ubiEnvMonTemperatureEntry 6 }

   
-- *****************************************************************
-- ubiEnvMonFanTable
-- ****************************************************************

	ubiEnvMonFanTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbiEnvMonFanEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of fan status maintained by the environmental
                monitor."
        ::= { ubiEnvMonObjects 2 }

	ubiEnvMonFanEntry OBJECT-TYPE
        SYNTAX     UbiEnvMonFanEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the fan status table, representing the status of
                the associated fan maintained by the environmental monitor."
        INDEX   { ubiEnvMonFanIndex }
        ::= { ubiEnvMonFanTable 1 }

	UbiEnvMonFanEntry ::=
        SEQUENCE {
                ubiEnvMonFanIndex       		Integer32,
                ubiEnvMonFanDescr       		DisplayString,
                ubiEnvMonFanState             	UbiEnvMonState
        }

	ubiEnvMonFanIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the fan being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ubiEnvMonFanEntry 1 }

	ubiEnvMonFanDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..255))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the fan being instrumented."
        ::= { ubiEnvMonFanEntry 2 }

	ubiEnvMonFanState OBJECT-TYPE
        SYNTAX     UbiEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the fan being instrumented.
                 Represents the fan state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.         
                                    
                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.  
                                     
                 notFunctioning(6): the environmental monitor does not 
                                    function properly.
               "

        ::= { ubiEnvMonFanEntry 3 }



-- *****************************************************************
-- ubiEnvMonSupplyTable
-- ****************************************************************

	ubiEnvMonSupplyTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbiEnvMonSupplyEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of power supply status maintained by the
                environmental monitor card."
        ::= { ubiEnvMonObjects 3 }

	ubiEnvMonSupplyEntry OBJECT-TYPE
        SYNTAX     UbiEnvMonSupplyEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the power supply status table, representing the
                status of the associated power supply maintained by the
                environmental monitor card."
        INDEX   { ubiEnvMonSupplyIndex }
        ::= { ubiEnvMonSupplyTable 1  }

	UbiEnvMonSupplyEntry ::=
        SEQUENCE {
                ubiEnvMonSupplyIndex    		Integer32,
                ubiEnvMonSupplyDescr    		DisplayString,
                ubiEnvMonSupplyState          	UbiEnvMonState,
                ubiEnvMonSupplySource         	INTEGER,
                ubiEnvMonExternalAlarmAc        INTEGER,
                ubiEnvMonExternalAlarmUnit      INTEGER
         }

	ubiEnvMonSupplyIndex OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the power supply being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ubiEnvMonSupplyEntry 1 }

	ubiEnvMonSupplyDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..255))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the power supply 
                being instrumented."
        ::= { ubiEnvMonSupplyEntry 2 }

	ubiEnvMonSupplyState OBJECT-TYPE
        SYNTAX     UbiEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the power supply 
                 being instrumented.  
                 Represents the power state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.         
                                    
                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.  
                                     
                 notFunctioning(6): the environmental monitor does not 
                                    function properly.
                "
        ::= { ubiEnvMonSupplyEntry 3 }

	ubiEnvMonSupplySource OBJECT-TYPE
        SYNTAX INTEGER {           
        				none(0),
                        ac(1),
                        dc(2)
        }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The power supply source.
                 ac      - AC power supply
                 dc      - DC power supply"
        ::= { ubiEnvMonSupplyEntry 4 }  
        
    ubiEnvMonExternalAlarmAc OBJECT-TYPE
        SYNTAX INTEGER {
					normal(1),
					fail(2)
		}        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The power supply convertor AC.
                 nomal (1)       
                 fail  (2)"      
        ::= { ubiEnvMonSupplyEntry 5 }

	ubiEnvMonExternalAlarmUnit OBJECT-TYPE
        SYNTAX INTEGER {
					normal(1),
					fail(2)
		}
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The power supply convertor unit.
                 nomal (1)       
                 fail  (2)"      
        ::= { ubiEnvMonSupplyEntry 6 }

    
-- *****************************************************************
-- ubiEnvMonSupplyChannelTable
-- ****************************************************************

	ubiEnvMonSupplyChannelTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF UbiEnvMonSupplyChannelEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table represents the extension status 
                for DC power supply."
        ::= { ubiEnvMonObjects 4 }

	ubiEnvMonSupplyChannelEntry OBJECT-TYPE
        SYNTAX     UbiEnvMonSupplyChannelEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in this table, representing the extended status of 
                the associated DC power supply maintained by 
                the environmental monitor card."
        INDEX   { ubiEnvMonSupplyIndex, ubiEnvMonSupplyChannelType }
        ::= { ubiEnvMonSupplyChannelTable 1  }

	UbiEnvMonSupplyChannelEntry ::=
        SEQUENCE {
                ubiEnvMonSupplyChannelType  			INTEGER,
                ubiEnvMonSupplyChannelState      		UbiEnvMonState
        }

	ubiEnvMonSupplyChannelType OBJECT-TYPE
        SYNTAX     INTEGER
        {
        	dc_48v_a(1),
        	dc_48v_b(2)
    	}  
    	MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Unique index for the DC power supply channel."
        ::= { ubiEnvMonSupplyChannelEntry 1 }


	ubiEnvMonSupplyChannelState OBJECT-TYPE
        SYNTAX     UbiEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the DC power supply channel 
                being instrumented.
                Represents the power state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.         
                                    
                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.  
                                     
                 notFunctioning(6): the environmental monitor does not 
                                    function properly.
                "
        ::= { ubiEnvMonSupplyChannelEntry 2 }




-- *****************************************************************
-- ubiEnvMonMIBNotificationEnables
-- ****************************************************************   
	ubiEnvMonEnableTempStatusChange OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ubiEnvMonTempStatusChangeNotif.
                A false value prevents temperature notifications 
                from being sent by  this entity."
        DEFVAL { false }
        ::= { ubiEnvMonMIBNotificationEnables 1 }

	ubiEnvMonEnableFanStatusChange OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ubiEnvMonFanStatusChangeNotif.
                A false value prevents fan notifications 
                from being sent by  this entity."
        DEFVAL { false }
        ::= { ubiEnvMonMIBNotificationEnables 2 }

	ubiEnvMonEnableSupplyStatusChange OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ubiEnvMonSuppStatusChangeNotif. 
                A false value prevents redundant supply notifications
                from being generated by this system."
        DEFVAL { false }
        ::= { ubiEnvMonMIBNotificationEnables 3 }

	ubiEnvMonEnableSupplyChannelStatusChange OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ubiEnvMonSuppExtStatusChangeNotif. 
                A false value prevents redundant supply notifications
                from being generated by this system."
        DEFVAL { false }
        ::= { ubiEnvMonMIBNotificationEnables 4 }

-- *****************************************************************
-- ubiEnvMonMIBNotificationPrefix
-- ****************************************************************   
 

-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
-- that are backward compatible with SNMPv1 Traps.   
ubiEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ubiEnvMonMIBNotificationPrefix 0 }

 
	ubiEnvMonTempStatusChange NOTIFICATION-TYPE
        OBJECTS {
                ubiEnvMonTemperatureDescr,
                ubiEnvMonTemperatureValue,
                ubiEnvMonTemperatureState
                }
        STATUS  current
        DESCRIPTION
                "A ubiEnvMonTempStatusChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ubiEnvMonTemperatureState."
        ::= { ubiEnvMonMIBNotifications 1 }

	ubiEnvMonFanStatusChange NOTIFICATION-TYPE
        OBJECTS {
                ubiEnvMonFanDescr,
                ubiEnvMonFanState
                }
        STATUS  current
        DESCRIPTION
                "A ubiEnvMonFanStatusChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ubiEnvMonFanState."
        ::= { ubiEnvMonMIBNotifications 2 }

	ubiEnvMonSupplyStatusChange NOTIFICATION-TYPE
        OBJECTS {
                ubiEnvMonSupplyDescr,
                ubiEnvMonSupplyState
                }
        STATUS  current
        DESCRIPTION
                "A ubiEnvMonSupplyStatChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ubiEnvMonSupplyState."
        ::= { ubiEnvMonMIBNotifications 3 }
 
	ubiEnvMonSupplyChannelStatusChange NOTIFICATION-TYPE
        OBJECTS {
                ubiEnvMonSupplyDescr,   
                ubiEnvMonSupplyChannelType,
                ubiEnvMonSupplyChannelState
                }
        STATUS  current
        DESCRIPTION
                "A ubiEnvMonSuppExtStatusChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ubiEnvMonSupplyExtChannelStatus."
        ::= { ubiEnvMonMIBNotifications 4 }
 
 
-- *****************************************************************
-- ubiEnvMonMIBConformance
-- ****************************************************************  
 
-- conformance information
ubiEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 1 }
ubiEnvMonMIBGroups      OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 2 }


-- compliance statements

	ubiEnvMonMIBCompliance MODULE-COMPLIANCE
        STATUS  current
        DESCRIPTION
                "The compliance statement for entities which implement
                the Ubiquoss Environmental Monitor MIB."
        MODULE  -- this module
                MANDATORY-GROUPS { 
                		ubiEnvMonMIBGroup,
                		ubiEnvMonMIBNotifGroup
                }   
        GROUP ubiEnvMonMIBGroup
        DESCRIPTION
          	"The ubiEnvMonMIBGroup is applicable for implementations which
 			need to get the system environment information."           

        GROUP ubiEnvMonMIBNotifGroup
        DESCRIPTION
          	"The ubiEnvMonMIBNotifGroup must be
 			implemented for system environment that have notification."       
        ::= { ubiEnvMonMIBCompliances 1 }

-- units of conformance

	ubiEnvMonMIBGroup OBJECT-GROUP
        OBJECTS {
                ubiEnvMonTemperatureDescr,
                ubiEnvMonTemperatureValue,
                ubiEnvMonTemperatureHighThreshold,    
                ubiEnvMonTemperatureLowThreshold,
                ubiEnvMonTemperatureLastShutdown,
                ubiEnvMonTemperatureState,

                ubiEnvMonFanDescr,
                ubiEnvMonFanState,

                ubiEnvMonSupplyDescr,
                ubiEnvMonSupplyState,
                ubiEnvMonSupplySource,    
                
                ubiEnvMonSupplyExtChannel,
                ubiEnvMonSupplyExtChannelState,

                ubiEnvMonEnableTempStatusChangeNotif,
                ubiEnvMonEnableFanStatusChangeNotif,
                ubiEnvMonEnableSuppStatusChangeNotif,
                ubiEnvMonEnableSuppExtStatusChangeNotif

        }
        STATUS  current
        DESCRIPTION
                "A collection of objects providing environmental 
                monitoring capability to a ubi chassis."
        ::= { ubiEnvMonMIBGroups 1 }

	ubiEnvMonMIBNotifGroup NOTIFICATION-GROUP
        NOTIFICATIONS  {
                 ubiEnvMonTempStatusChangeNotif,
                 ubiEnvMonFanStatusChangeNotif,
                 ubiEnvMonSuppStatusChangeNotif,
                 ubiEnvMonSuppExtStatusChangeNotif
        }
        STATUS current
        DESCRIPTION
                "A notification group providing notification
                 for environmental monitoring. "
        ::= { ubiEnvMonMIBGroups 2 }    
        
END