-- Accedian Enterprise Specific MIB
--
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--


ACD-SA-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Unsigned32, Gauge32
        FROM SNMPv2-SMI
    DisplayString, DateAndTime, TEXTUAL-CONVENTION, RowStatus
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF

    acdMibs
        FROM ACCEDIAN-SMI;

acdSa MODULE-IDENTITY

    LAST-UPDATED "201112210100Z"
    ORGANIZATION "Accedian Networks, Inc."
    CONTACT-INFO
            "Accedian Technical Assistance Center
             Accedian Networks, Inc.
             4878 Levy, suite 202
             Saint-Laurent, Quebec Canada H4R 2P1
             E-mail: support@accedian.com"
    DESCRIPTION
            "The Service Availability database for this Accedian Networks device."

    REVISION "201112210100Z"        -- 21 Dec 2011
    DESCRIPTION
            "Add support for ETH-SLM metrics."


    REVISION "201103150100Z"        -- 15 Mars 2011
    DESCRIPTION
            "Initial version of MIB module ACD-SA-MIB."

    ::= { acdMibs 12 }

acdSaNotifications      OBJECT IDENTIFIER ::= { acdSa 0 }
acdSaMIBObjects         OBJECT IDENTIFIER ::= { acdSa 1 }
acdSaConformance        OBJECT IDENTIFIER ::= { acdSa 2 }
                        
acdSaConfig             OBJECT IDENTIFIER ::= { acdSaMIBObjects 1 }
acdSaCounter            OBJECT IDENTIFIER ::= { acdSaMIBObjects 2 }
acdSaStatus             OBJECT IDENTIFIER ::= { acdSaMIBObjects 3 }

---------------------------------------------------------------------------
-- Textual conventions
---------------------------------------------------------------------------

AcdSaMetricType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "A value that represents a type of metric that can be used in an
        instance of Service Availability."
    SYNTAX      INTEGER {
                    metricPaaPlr(1),
                    metricPaaOwDelay(2),
                    metricPaaOwDv(3),
                    metricPaaTwDelay(4),
                    metricPaaTwDv(5),
                    metricCfmPlr(6),
                    metricCfmOwDelay(7),
                    metricCfmOwDv(8),
                    metricCfmTwDelay(9),
                    metricCfmTwDv(10),
		    metricCfmSlmNearEndPlr(11),
		    metricCfmSlmFarEndPlr(12)
    }
    
AcdSaValidFlag ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "The validity flag can have three values: valid, adjusted, or pending.
        The value of valid indicates the metrics are calculated normally. 
	The value of adjusted is used to indicate a change occurred in the 
	configuration during the reporting period which may impact the service 
	availability calculation. 
	The value of pending indicates that the counters were reset in the 
	middle of a time interval."
    SYNTAX      INTEGER {
                    valid(1),
                    adjusted(2),
                    pending(3)
    }
    
AcdSaAdminStateFlag ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "This flag is used for the administrative state.
        The value IS indicates the state is In-Service. The value OOS
	indicates the state is Out-of-Service."
    SYNTAX      INTEGER {
                    is(1),
                    oos(2)
    }
    
AcdSaOperStateFlag ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
       "This flag is used for the operational state.
        The value IS indicates the state is In-Service. The value OOS
	indicates the state is Out-of-Service. The value oos-au indicates
	the state is Out-of-Service-Autonomous. This state is entered when
	all of the metrics associated with the service instance are disabled."
    SYNTAX      INTEGER {
                    is(1),
                    oos(2),
                    oosAu(3)
    }
    
---------------------------------------------------------------------------
 -- The Service configuration table
 -- This table contains all Service entry configurations.
---------------------------------------------------------------------------

acdSaServiceConfigTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaServiceConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaConfig 1 }

acdSaServiceConfigEntry OBJECT-TYPE
    SYNTAX      AcdSaServiceConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all settings for a Service."
    INDEX   { acdSaServiceIndex }
    ::=  { acdSaServiceConfigTable 1 }

AcdSaServiceConfigEntry ::= SEQUENCE {
    acdSaServiceIndex                   Unsigned32,
    acdSaServiceConfigRowStatus         RowStatus,
    acdSaServiceConfigName              DisplayString,    
    acdSaServiceConfigAdminState        AcdSaAdminStateFlag,
    acdSaServiceConfigReportingPeriod   Unsigned32,
    acdSaServiceConfigUaWindowSize      Unsigned32,
    acdSaServiceConfigHliWindowSize     Unsigned32,
    acdSaServiceConfigTimeInterval      Unsigned32
}

acdSaServiceIndex  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Unique value for each service instance."
    ::= { acdSaServiceConfigEntry 1 }

acdSaServiceConfigRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
       "All columns must have a valid value before a row can be activated. To
        create a new Service you shall provide a unique name for an empty
        row with the RowStatus set to Create and Go."
    ::= { acdSaServiceConfigEntry 2 }

acdSaServiceConfigName  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A unique name used to identify the Service."
    ::= { acdSaServiceConfigEntry 3 }

acdSaServiceConfigAdminState OBJECT-TYPE
    SYNTAX      AcdSaAdminStateFlag
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Administrative state is(1) or oos(2)."
    DEFVAL      { 2 }
    ::= { acdSaServiceConfigEntry 4 }

acdSaServiceConfigReportingPeriod OBJECT-TYPE
    SYNTAX      Unsigned32 (1 .. 1440)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "A reporting period over which availability counters are evaluated
        in addition to the monotonic counters (In minutes)."
    DEFVAL      { 15 }
    ::= { acdSaServiceConfigEntry 5 }

acdSaServiceConfigUaWindowSize OBJECT-TYPE
    SYNTAX      Unsigned32 (1 .. 1000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The number of consecutive seconds over which to assess unavailability."
    DEFVAL      { 10 }
    ::= { acdSaServiceConfigEntry 6 }

acdSaServiceConfigHliWindowSize OBJECT-TYPE
    SYNTAX      Unsigned32 (1 .. 999)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The number of consecutive Time Intervals used to assess High Loss Intervals for this instance."
    DEFVAL      { 3 }
    ::= { acdSaServiceConfigEntry 7 }
    
acdSaServiceConfigTimeInterval OBJECT-TYPE
    SYNTAX      Unsigned32 (1 .. 60)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The interval of time during which the metric is evaluated. Allowed values
	are 1, 5, 10, 20, or 60."
    DEFVAL      { 1 }
    ::= { acdSaServiceConfigEntry 8 }

    
---------------------------------------------------------------------------
 -- The Metric configuration table
 -- This table contains all Metric entry configurations.
---------------------------------------------------------------------------

acdSaMetricConfigTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaMetricConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ....."
    ::= { acdSaConfig 2 }

acdSaMetricConfigEntry OBJECT-TYPE
    SYNTAX      AcdSaMetricConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all settings for a Metric."
    INDEX   { acdSaServiceIndex,
              acdSaMetricIndex }
    ::=  { acdSaMetricConfigTable 1 }

AcdSaMetricConfigEntry ::= SEQUENCE {
    acdSaMetricIndex                 Unsigned32,
    acdSaMetricConfigRowStatus          RowStatus,
    acdSaMetricConfigName               DisplayString,
    acdSaMetricConfigSrcName		DisplayString,
    acdSaMetricConfigType               AcdSaMetricType,
    acdSaMetricConfigThreshold     	Unsigned32
}

acdSaMetricIndex  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Index for each metric instance."
    ::= { acdSaMetricConfigEntry 1 }

acdSaMetricConfigRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
       "All columns must have a valid value before a row can be activated. To
        create a new Service you shall provide the a unique name for an empty
        row with the RowStatus set to Create and Go.  To delete the VLAN set
        you need to set the RowStatus to destroy."
    ::= { acdSaMetricConfigEntry 2 }

acdSaMetricConfigName  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A unique name used to identify the Metric."
    ::= { acdSaMetricConfigEntry 3 }

acdSaMetricConfigSrcName  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A unique name used to identify the source metric."
    ::= { acdSaMetricConfigEntry 4 }

acdSaMetricConfigType OBJECT-TYPE
    SYNTAX      AcdSaMetricType
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Enable or disable the Service Availability entry."
    DEFVAL      { metricCfmTwDelay }
    ::= { acdSaMetricConfigEntry 5 }

acdSaMetricConfigThreshold  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Indicates the delay threshold for this metric when type is 
	one of metric delay parameters (in micro-seconds). Indicates
	the packet loss threshold for this metric when type is one of
	packet-loss parameter expressed in millionth of percent
	(1,000,000 is 1%)."
     DEFVAL      { 0 }
    ::= { acdSaMetricConfigEntry 6 }


---------------------------------------------------------------------------
 -- The Service counters table
 -- This table contains all services history counters.
---------------------------------------------------------------------------

acdSaServiceCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaServiceCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 1 }

acdSaServiceCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaServiceCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all counters for a Service."
    INDEX   { acdSaServiceIndex }
    ::=  { acdSaServiceCounterTable 1 }

AcdSaServiceCounterEntry ::= SEQUENCE {
    acdSaServiceCounterPeriodIndex      Unsigned32,
    acdSaServiceCounterValidFlag        AcdSaValidFlag,
    acdSaServiceCounterUpTime           Unsigned32,
    acdSaServiceCounterUaTime           Unsigned32,
    acdSaServiceCounterMaintTime        Unsigned32,
    acdSaServiceCounterAvailRatio       Unsigned32,
    acdSaServiceCounterGaps             Unsigned32,
    acdSaServiceCounterLargestGap       Unsigned32,
    acdSaServiceCounterChliTime         Unsigned32,
    acdSaServiceCounterChliRatio        Unsigned32
}

acdSaServiceCounterPeriodIndex  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An index that uniquely identifies the particular sample this entry
         represents among all samples associated with the same service
         instance. This index starts at 1 and increases by one as each new
         period."
    ::= { acdSaServiceCounterEntry 1 }

acdSaServiceCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the service counter during this sampling
         interval."
    ::= { acdSaServiceCounterEntry 2 }


acdSaServiceCounterUpTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Uptime is a measure of the time a service has been up during this
         sampling interval."
    ::= { acdSaServiceCounterEntry 3 }

acdSaServiceCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a service has been unavailable
         during this sampling interval."
    ::= { acdSaServiceCounterEntry 4 }

acdSaServiceCounterMaintTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The MaintTime is a measure of the time a service has been in maintenance
         during this sampling interval."
    ::= { acdSaServiceCounterEntry 5 }

acdSaServiceCounterAvailRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the availability ratio in millionth of a percent
        (1,000,000 is 1%)."
    ::= { acdSaServiceCounterEntry 6 }


acdSaServiceCounterGaps  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The gap shall be the number of time the state change from available
         to unavailable."
    ::= { acdSaServiceCounterEntry 7 }

acdSaServiceCounterLargestGap  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The largest gap shall be the largest number of consecutive unavailable
         second."
    ::= { acdSaServiceCounterEntry 8 }

acdSaServiceCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The CHLI time is a counter which increments for every high loss interval. 
	 It is only reset to zero when one of the following conditions occur: 
	 1) device reboot 2) explicit counter reset."
    ::= { acdSaServiceCounterEntry 9 }

acdSaServiceCounterChliRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ratio of high loss intervals divided by the uptime minus the sum of 
	maintenance time and unavailable time, expressed in millionth of a percent (1,000,000 is 1%)."
    ::= { acdSaServiceCounterEntry 10 }


---------------------------------------------------------------------------
 -- The Service History counters table
 -- This table contains all services history counters.
---------------------------------------------------------------------------

acdSaServiceHistCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaServiceHistCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 2 }

acdSaServiceHistCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaServiceHistCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all counters for a Service."
    INDEX   { acdSaServiceIndex,
              acdSaServiceHistCounterPeriodIndex }
    ::=  { acdSaServiceHistCounterTable 1 }

AcdSaServiceHistCounterEntry ::= SEQUENCE {
    acdSaServiceHistCounterPeriodIndex      Unsigned32,
    acdSaServiceHistCounterIntervalEnd      DateAndTime,
    acdSaServiceHistCounterValidFlag        AcdSaValidFlag,
    acdSaServiceHistCounterUpTime           Unsigned32,
    acdSaServiceHistCounterUaTime           Unsigned32,
    acdSaServiceHistCounterMaintTime        Unsigned32,
    acdSaServiceHistCounterAvailRatio       Unsigned32,
    acdSaServiceHistCounterGaps             Unsigned32,
    acdSaServiceHistCounterLargestGap       Unsigned32,
    acdSaServiceHistCounterChliTime         Unsigned32,
    acdSaServiceHistCounterChliRatio        Unsigned32
}

acdSaServiceHistCounterPeriodIndex  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An index that uniquely identifies the particular sample this entry
         represents among all samples associated with the same service
         instance. This index starts at 1 and increases by one as each new
         period."
    ::= { acdSaServiceHistCounterEntry 1 }


acdSaServiceHistCounterIntervalEnd  OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This is the time of the end of this entry."
    ::= { acdSaServiceHistCounterEntry 2 }


acdSaServiceHistCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the service counter during this sampling
         interval."
    ::= { acdSaServiceHistCounterEntry 3 }


acdSaServiceHistCounterUpTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Uptime is a measure of the time a service has been up during this
         sampling interval."
    ::= { acdSaServiceHistCounterEntry 4 }

acdSaServiceHistCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a service has been unavailable
         during this sampling interval."
    ::= { acdSaServiceHistCounterEntry 5 }

acdSaServiceHistCounterMaintTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The MaintTime is a measure of the time a service has been in maintenance
         during this sampling interval."
    ::= { acdSaServiceHistCounterEntry 6 }

acdSaServiceHistCounterAvailRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the availability ratio in millionth of a percent
        (1,000,000 is 1%)."
    ::= { acdSaServiceHistCounterEntry 7 }


acdSaServiceHistCounterGaps  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The gap shall be the number of time the state change from available
         to unavailable."
    ::= { acdSaServiceHistCounterEntry 8 }

acdSaServiceHistCounterLargestGap  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The largest gap shall be the largest number of consecutive unavailable
         second."
    ::= { acdSaServiceHistCounterEntry 9 }

acdSaServiceHistCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The CHLI time is a counter which increments for every High Loss Interval.
	 It is only reset to zero when one of the following conditions occur:
	 1) device reboot 2) explicit counter reset."
    ::= { acdSaServiceHistCounterEntry 10 }

acdSaServiceHistCounterChliRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ratio of high loss intervals divided by the uptime minus the sum of 
	maintenance time and unavailable time, expressed in millionth of a percent (1,000,000 is 1%)."
    ::= { acdSaServiceHistCounterEntry 11 }

---------------------------------------------------------------------------
 -- The Monotonic Service counters table
 -- This table contains all services monotonic counters.
---------------------------------------------------------------------------

acdSaServiceMonoCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaServiceMonoCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 3 }

acdSaServiceMonoCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaServiceMonoCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all monotonic counters for a Service."
    INDEX   { acdSaServiceIndex }
    ::=  { acdSaServiceMonoCounterTable 1 }

AcdSaServiceMonoCounterEntry ::= SEQUENCE {
    acdSaServiceMonoCounterValidFlag        AcdSaValidFlag,
    acdSaServiceMonoCounterUpTime           Unsigned32,
    acdSaServiceMonoCounterUaTime           Unsigned32,
    acdSaServiceMonoCounterMaintTime        Unsigned32,
    acdSaServiceMonoCounterAvailRatio       Unsigned32,
    acdSaServiceMonoCounterGaps             Unsigned32,
    acdSaServiceMonoCounterLargestGap       Unsigned32,
    acdSaServiceMonoCounterChliTime         Unsigned32,
    acdSaServiceMonoCounterChliRatio        Unsigned32
}

acdSaServiceMonoCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the service counter during this sampling
         interval."
    ::= { acdSaServiceMonoCounterEntry 1 }


acdSaServiceMonoCounterUpTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Uptime is a measure of the time a service has been up during this
         sampling interval."
    ::= { acdSaServiceMonoCounterEntry 2 }

acdSaServiceMonoCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a service has been unavailable
         during this sampling interval."
    ::= { acdSaServiceMonoCounterEntry 3 }

acdSaServiceMonoCounterMaintTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The MaintTime is a measure of the time a service has been in maintenance
         during this sampling interval."
    ::= { acdSaServiceMonoCounterEntry 4 }

acdSaServiceMonoCounterAvailRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the availability ratio in millionth of a percent
        (1,000,000 is 1%)."
    ::= { acdSaServiceMonoCounterEntry 5 }


acdSaServiceMonoCounterGaps  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The gap shall be the number of time the state change from available
         to unavailable."
    ::= { acdSaServiceMonoCounterEntry 6 }

acdSaServiceMonoCounterLargestGap  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The largest gap shall be the largest number of consecutive unavailable
         second."
    ::= { acdSaServiceMonoCounterEntry 7 }

acdSaServiceMonoCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A counter which increments for every high loss interval. 
	 It is only reset to zero when one of the following conditions occur: 
	 1) device reboot 2) explicit counter reset."
    ::= { acdSaServiceMonoCounterEntry 8 }

acdSaServiceMonoCounterChliRatio  OBJECT-TYPE
    SYNTAX      Unsigned32 (0..100000000)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ratio of high loss intervals divided by the uptime minus the sum of maintenance time and unavailable time,
	 expressed in millionth of a percent (1,000,000 is 1%)."
    ::= { acdSaServiceMonoCounterEntry 9 }


---------------------------------------------------------------------------
 -- The Metric counters table
 -- This table contains all metrics history counters.
---------------------------------------------------------------------------

acdSaMetricCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaMetricCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 4 }

acdSaMetricCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaMetricCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all counters for a Metric."
    INDEX   { acdSaServiceIndex,
	      acdSaMetricIndex }
    ::=  { acdSaMetricCounterTable 1 }

AcdSaMetricCounterEntry ::= SEQUENCE {
    acdSaMetricCounterValidFlag        AcdSaValidFlag,
    acdSaMetricCounterUaTime           Unsigned32,
    acdSaMetricCounterChliTime         Unsigned32
}

acdSaMetricCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the metric counter during this sampling
         interval."
    ::= { acdSaMetricCounterEntry 1 }


acdSaMetricCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a metric has been unavailable
         during this sampling interval."
    ::= { acdSaMetricCounterEntry 2 }

acdSaMetricCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A counter which increments for every High Loss Interval. It is only reset to zero when one of the following conditions occur: 
	 1) device reboot 2) explicit counter reset."
    ::= { acdSaMetricCounterEntry 3 }


---------------------------------------------------------------------------
 -- The Metric History counters table
 -- This table contains all metrics history counters.
---------------------------------------------------------------------------

acdSaMetricHistCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaMetricHistCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 5 }

acdSaMetricHistCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaMetricHistCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all counters for a Metric."
    INDEX   { acdSaMetricHistCounterID,
              acdSaMetricHistCounterPeriodIndex }
    ::=  { acdSaMetricHistCounterTable 1 }

AcdSaMetricHistCounterEntry ::= SEQUENCE {
    acdSaMetricHistCounterID               Unsigned32,
    acdSaMetricHistCounterPeriodIndex      Unsigned32,
    acdSaMetricHistCounterIntervalEnd      DateAndTime,
    acdSaMetricHistCounterValidFlag        AcdSaValidFlag,
    acdSaMetricHistCounterUaTime           Unsigned32,
    acdSaMetricHistCounterChliTime         Unsigned32
}

acdSaMetricHistCounterID  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Unique value for each Metric instance. This value follows the
         ordering of the service table."
    ::= { acdSaMetricHistCounterEntry 1 }

acdSaMetricHistCounterPeriodIndex  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An index that uniquely identifies the particular sample this entry
         represents among all samples associated with the same service
         instance. This index starts at 1 and increases by one as each new
         period."
    ::= { acdSaMetricHistCounterEntry 2 }


acdSaMetricHistCounterIntervalEnd  OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "This is the time of the end of this entry."
    ::= { acdSaMetricHistCounterEntry 3 }


acdSaMetricHistCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the metric counter during this sampling
         interval."
    ::= { acdSaMetricHistCounterEntry 4 }


acdSaMetricHistCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a metric has been unavailable
         during this sampling interval."
    ::= { acdSaMetricHistCounterEntry 5 }

acdSaMetricHistCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A counter which increments for every High Loss Interval. It is only reset to zero when one of the following conditions occur: 
	1) device reboot 2) explicit counter reset."
    ::= { acdSaMetricHistCounterEntry 6 }

---------------------------------------------------------------------------
 -- The Metric counters table
 -- This table contains all metrics history counters.
---------------------------------------------------------------------------

acdSaMetricMonoCounterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaMetricMonoCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaCounter 6 }

acdSaMetricMonoCounterEntry OBJECT-TYPE
    SYNTAX      AcdSaMetricMonoCounterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all counters for a Metric."
    INDEX   { acdSaServiceIndex,
	    acdSaMetricIndex }
    ::=  { acdSaMetricMonoCounterTable 1 }

AcdSaMetricMonoCounterEntry ::= SEQUENCE {
    acdSaMetricMonoCounterValidFlag        AcdSaValidFlag,
    acdSaMetricMonoCounterUaTime           Unsigned32,
    acdSaMetricMonoCounterChliTime         Unsigned32
}

acdSaMetricMonoCounterValidFlag  OBJECT-TYPE
    SYNTAX      AcdSaValidFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indicates the validity of the metric counter during this sampling
         interval."
    ::= { acdSaMetricMonoCounterEntry 1 }


acdSaMetricMonoCounterUaTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The UaTime is a measure of the time a metric has been unavailable
         during this sampling interval."
    ::= { acdSaMetricMonoCounterEntry 2 }

acdSaMetricMonoCounterChliTime  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A counter which increments for every high loss interval. It is only reset to zero when one of the following conditions occur: 
	 1) device reboot 2) explicit counter reset."
    ::= { acdSaMetricMonoCounterEntry 3 }



---------------------------------------------------------------------------
 -- The Service status table
 -- This table contains all Service entry status.
---------------------------------------------------------------------------

acdSaServiceStatusTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AcdSaServiceStatusEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains all instance of service availability of this unit."
    ::= { acdSaStatus 1 }

acdSaServiceStatusEntry OBJECT-TYPE
    SYNTAX      AcdSaServiceStatusEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry consisting of all status for a Service."
    INDEX   { acdSaServiceStatusID }
    ::=  { acdSaServiceStatusTable 1 }

AcdSaServiceStatusEntry ::= SEQUENCE {
    acdSaServiceStatusID                Unsigned32,
    acdSaServiceStatusName              DisplayString,    
    acdSaServiceStatusAdminState        AcdSaAdminStateFlag,
    acdSaServiceStatusOperState         AcdSaOperStateFlag,
    acdSaServiceStatusNbrMetrics   	Gauge32
}

acdSaServiceStatusID  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Unique value for each service instance."
    ::= { acdSaServiceStatusEntry 1 }

acdSaServiceStatusName  OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A unique name used to identify the Service."
    ::= { acdSaServiceStatusEntry 2 }

acdSaServiceStatusAdminState OBJECT-TYPE
    SYNTAX      AcdSaAdminStateFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Administrative state is one of is(1) or oos(2)."
    DEFVAL      { 2 }
    ::= { acdSaServiceStatusEntry 3 }

acdSaServiceStatusOperState OBJECT-TYPE
    SYNTAX      AcdSaOperStateFlag
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational state is one of is(1), oos(2) or oosAu (3)."
    DEFVAL      { 2 }
    ::= { acdSaServiceStatusEntry 4 }

acdSaServiceStatusNbrMetrics OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of metrics associated with this Service instance."
    DEFVAL      { 0 }
    ::= { acdSaServiceStatusEntry 5 }





---------------------------------------------------------------------------
 -- ACD-SA-MIB Module - Conformance Information
---------------------------------------------------------------------------

acdSaCompliances    OBJECT IDENTIFIER ::= { acdSaConformance 1 }
acdSaGroups         OBJECT IDENTIFIER ::= { acdSaConformance 2 }
                    
---------------------------------------------------------------------------
 -- Units of conformance
---------------------------------------------------------------------------

acdSaServiceConfigGroup OBJECT-GROUP
    OBJECTS {
        acdSaServiceConfigRowStatus,
        acdSaServiceConfigName,
        acdSaServiceConfigAdminState,
        acdSaServiceConfigReportingPeriod,
        acdSaServiceConfigUaWindowSize,
        acdSaServiceConfigHliWindowSize,
        acdSaServiceConfigTimeInterval
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Service configuration Group."
    ::= { acdSaGroups 1 }

acdSaMetricConfigGroup OBJECT-GROUP
    OBJECTS {
        acdSaMetricConfigRowStatus,
        acdSaMetricConfigName,
        acdSaMetricConfigSrcName,
        acdSaMetricConfigType,
        acdSaMetricConfigThreshold
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Metric configuration Group."
    ::= { acdSaGroups 2 }

acdSaServiceCounterGroup OBJECT-GROUP
    OBJECTS {    
        acdSaServiceCounterPeriodIndex,    
        acdSaServiceCounterValidFlag,
        acdSaServiceCounterUpTime,
        acdSaServiceCounterUaTime,
        acdSaServiceCounterMaintTime,
        acdSaServiceCounterAvailRatio,
        acdSaServiceCounterGaps,
        acdSaServiceCounterLargestGap,
        acdSaServiceCounterChliTime,
        acdSaServiceCounterChliRatio
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Service Counter Group."
    ::= { acdSaGroups 3 }

acdSaServiceHistCounterGroup OBJECT-GROUP
    OBJECTS {
    
        acdSaServiceHistCounterIntervalEnd,
        acdSaServiceHistCounterValidFlag,
        acdSaServiceHistCounterUpTime,
        acdSaServiceHistCounterUaTime,
        acdSaServiceHistCounterMaintTime,
        acdSaServiceHistCounterAvailRatio,
        acdSaServiceHistCounterGaps,
        acdSaServiceHistCounterLargestGap,
        acdSaServiceHistCounterChliTime,
        acdSaServiceHistCounterChliRatio
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Service History Counter Group."
    ::= { acdSaGroups 4 }

acdSaServiceMonoCounterGroup OBJECT-GROUP
    OBJECTS {
        acdSaServiceMonoCounterValidFlag,
        acdSaServiceMonoCounterUpTime,
        acdSaServiceMonoCounterUaTime,
        acdSaServiceMonoCounterMaintTime,
        acdSaServiceMonoCounterAvailRatio,
        acdSaServiceMonoCounterGaps,
        acdSaServiceMonoCounterLargestGap,
        acdSaServiceMonoCounterChliTime,
        acdSaServiceMonoCounterChliRatio
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Service Monotonic Counter Group."
    ::= { acdSaGroups 5 }

acdSaMetricCounterGroup OBJECT-GROUP
    OBJECTS {
        acdSaMetricCounterValidFlag,
        acdSaMetricCounterUaTime,
        acdSaMetricCounterChliTime
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Metric Counter Group."
    ::= { acdSaGroups 6 }

acdSaMetricHistCounterGroup OBJECT-GROUP
    OBJECTS {
    
        acdSaMetricHistCounterIntervalEnd,
        acdSaMetricHistCounterValidFlag,
        acdSaMetricHistCounterUaTime,
        acdSaMetricHistCounterChliTime
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Metric History Counter Group."
    ::= { acdSaGroups 7 }

acdSaMetricMonoCounterGroup OBJECT-GROUP
    OBJECTS {
        acdSaMetricMonoCounterValidFlag,
        acdSaMetricMonoCounterUaTime,
        acdSaMetricMonoCounterChliTime
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Metric History Counter Group."
    ::= { acdSaGroups 8 }

acdSaServiceStatusGroup OBJECT-GROUP
    OBJECTS {
	acdSaServiceStatusName,
	acdSaServiceStatusAdminState,
	acdSaServiceStatusOperState,
	acdSaServiceStatusNbrMetrics
    }
    STATUS      current
    DESCRIPTION
       "Objects for the Service Status Group."
    ::= { acdSaGroups 9 }


acdSaCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
       "The compliance statement for support of the ACD-SA-MIB module."
    MODULE
        MANDATORY-GROUPS {
            acdSaServiceConfigGroup,
            acdSaMetricConfigGroup,
            acdSaServiceCounterGroup,
            acdSaServiceHistCounterGroup,
            acdSaServiceMonoCounterGroup,
            acdSaMetricCounterGroup,
            acdSaMetricHistCounterGroup,
            acdSaMetricMonoCounterGroup,
	  acdSaServiceStatusGroup
         }

    OBJECT  acdSaServiceConfigRowStatus
      SYNTAX       RowStatus { active(1) }
      WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
      DESCRIPTION "Support for createAndWait is not required."

    OBJECT  acdSaMetricConfigRowStatus
      SYNTAX       RowStatus { active(1) }
      WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
      DESCRIPTION "Support for createAndWait is not required."

    ::= { acdSaCompliances 1 }

END