    IPI-CMM-IPMI-MIB DEFINITIONS ::= BEGIN

    --  This module provides authoritative definitions for ipmi device
    --  controlled by BMC
    --
    --  This module will be extended, as needed.
    --

    IMPORTS
        OBJECT-TYPE, MODULE-IDENTITY,
        Gauge32, Counter32, Unsigned32,
        TimeTicks, NOTIFICATION-TYPE
            FROM SNMPv2-SMI
        DateAndTime, DisplayString,
        MacAddress, RowStatus, TEXTUAL-CONVENTION
            FROM SNMPv2-TC
        MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
            FROM SNMPv2-CONF
        enterprises,OBJECT-IDENTITY
            FROM SNMPv2-SMI
    ipi FROM IPI-MODULE-MIB
    cmmChassisObject,
    cmmStackUnitIndex FROM IPI-CMM-CHASSIS-MIB;

	cmm  MODULE-IDENTITY
	LAST-UPDATED "202008060000Z"   -- Jun 08, 2020 12:00:00 GMT
  ORGANIZATION "IP Infusion"
  CONTACT-INFO "support@ipinfusion.com"

	DESCRIPTION
	   "The Structure of CMM Management Information for
	    the IPI enterprise."
  REVISION "202008060000Z"
  DESCRIPTION
      "Complying to level 3 of SMILINT"
::= { ipi 100 }


    -- ### Groups ###

    cmmIpmiDeviceObjects       OBJECT IDENTIFIER ::={ cmmChassisObject 5 }
    cmmIpmiDeviceAlarmObjects       OBJECT IDENTIFIER ::={ cmmChassisObject 6 }

  cmmIpmiDeviceSensorTable     OBJECT-TYPE
        SYNTAX        SEQUENCE OF CmmIpmiDeviceSensorEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
        "A list of entries containing sensor information
        for BMC controlled devices."
        ::= { cmmIpmiDeviceObjects 1 }

    cmmIpmiDeviceSensorEntry    OBJECT-TYPE
        SYNTAX        CmmIpmiDeviceSensorEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
        "A list of entries containing sensor information
        for BMC controlled devices."
        INDEX    { cmmIpmiDeviceSensorIndex }
          ::= { cmmIpmiDeviceSensorTable 1 }

    CmmIpmiDeviceSensorEntry    ::=
          SEQUENCE {
            cmmIpmiDeviceSensorIndex                INTEGER,
            cmmIpmiDeviceSensorName                 DisplayString,
            cmmIpmiDeviceSensorValue                INTEGER,
            cmmIpmiDeviceSensorUnits                DisplayString,
            cmmIpmiDeviceSensorState                DisplayString,
            cmmIpmiDeviceSensorLowerNonRecover      INTEGER,
            cmmIpmiDeviceSensorLowerCritical        INTEGER,
            cmmIpmiDeviceSensorLowerNonCritical     INTEGER,
            cmmIpmiDeviceSensorUpperNonCritical     INTEGER,
            cmmIpmiDeviceSensorUpperCritical        INTEGER,
            cmmIpmiDeviceSensorUpperNonRecover      INTEGER
          }

      cmmIpmiDeviceSensorIndex   OBJECT-TYPE
        SYNTAX        INTEGER (1..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
        "The unique sensor index number."
        ::= { cmmIpmiDeviceSensorEntry 1 }

      cmmIpmiDeviceSensorName OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The name of IPMI device sensor.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceSensorEntry 2 }

      cmmIpmiDeviceSensorValue  OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The value read for IPMI device sensor.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 3 }

      cmmIpmiDeviceSensorUnits   OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The unit of the value read for IPMI device sensor.
        For Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceSensorEntry 4 }

      cmmIpmiDeviceSensorState   OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The operating state of IPMI device sensor.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceSensorEntry 5 }

      cmmIpmiDeviceSensorLowerNonRecover   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor lower non recover value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 6 }

      cmmIpmiDeviceSensorLowerCritical   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor lower critical value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 7 }

      cmmIpmiDeviceSensorLowerNonCritical   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor lower non critical value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        -100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 8 }

      cmmIpmiDeviceSensorUpperNonCritical   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor upper non critical value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 9 }

      cmmIpmiDeviceSensorUpperCritical   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor upper critical value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 10 }

      cmmIpmiDeviceSensorUpperNonRecover   OBJECT-TYPE
        SYNTAX        INTEGER
        UNITS         "0.001 unit"
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "The IPMI device sensor upper non recover value.
        Unit: Temperature in degree C, Current in Amps,
          Power in Watts, Voltage in Volts, Fan-Speed in RPM.
        '-100002' indicates not applicable"
        ::= { cmmIpmiDeviceSensorEntry 11 }

  cmmIpmiDeviceFRUTable     OBJECT-TYPE
     SYNTAX        SEQUENCE OF CmmIpmiDeviceFRUEntry
     MAX-ACCESS    not-accessible
     STATUS        current
     DESCRIPTION
     "A list of entries containing FRU information
     for BMC controlled devices."
     ::= { cmmIpmiDeviceObjects 2 }

    cmmIpmiDeviceFRUEntry   OBJECT-TYPE
      SYNTAX        CmmIpmiDeviceFRUEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION
      "A list of entries containing FRU information
      for BMC controlled devices."
      INDEX    { cmmIpmiDeviceFRUIndex }
        ::= { cmmIpmiDeviceFRUTable 1 }

    CmmIpmiDeviceFRUEntry ::=
      SEQUENCE {
         cmmIpmiDeviceFRUIndex            INTEGER,
         cmmIpmiDeviceBoardMfgDate        DateAndTime,
         cmmIpmiDeviceBoardMfg            DisplayString,
         cmmIpmiDeviceBoardProduct        DisplayString,
         cmmIpmiDeviceBoardSerial         DisplayString,
         cmmIpmiDeviceBoardPartNum        DisplayString,
         cmmIpmiDeviceProductManufacturer DisplayString,
         cmmIpmiDeviceProductName         DisplayString,
         cmmIpmiDeviceProductPartNum      DisplayString,
         cmmIpmiDeviceProductVersion      DisplayString,
         cmmIpmiDeviceProductSerial       DisplayString,
         cmmIpmiDeviceProductAssetTag     DisplayString,
         cmmIpmiDeviceProductExtraInfo    DisplayString,
         cmmIpmiDeviceProductExtraInfo2   DisplayString,
         cmmIpmiDeviceDescription         DisplayString
      }

      cmmIpmiDeviceFRUIndex   OBJECT-TYPE
        SYNTAX        INTEGER (1..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
        "The unique FRU index number."
        ::= { cmmIpmiDeviceFRUEntry 1 }

      cmmIpmiDeviceBoardMfgDate OBJECT-TYPE
        SYNTAX        DateAndTime
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Board manufacturing date.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 2 }

      cmmIpmiDeviceBoardMfg OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Board manufacturer name.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 3 }

      cmmIpmiDeviceBoardProduct OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Board product name.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 4 }

      cmmIpmiDeviceBoardSerial  OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Board Serial number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 5 }

      cmmIpmiDeviceBoardPartNum OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Board Part number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 6 }

      cmmIpmiDeviceProductManufacturer OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product manufacturer name.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 7 }

      cmmIpmiDeviceProductName OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product name.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 8 }

      cmmIpmiDeviceProductPartNum OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product part number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 9 }

      cmmIpmiDeviceProductVersion OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product version number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 10 }

      cmmIpmiDeviceProductSerial OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product serial number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 11 }

      cmmIpmiDeviceProductAssetTag  OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product asset tag number.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 12 }

      cmmIpmiDeviceProductExtraInfo OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product extra information.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 13 }

      cmmIpmiDeviceProductExtraInfo2  OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Product extra information.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 14 }

      cmmIpmiDeviceDescription  OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
        "Device Description.
        Blank indicates unavailable"
        ::= { cmmIpmiDeviceFRUEntry 15 }
    --
    -- ## Notifications
    --

    cmmIpmiDeviceAlarmNotifications             OBJECT IDENTIFIER ::= { cmmIpmiDeviceAlarmObjects 1 }

    cmmIpmiDeviceLNC   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerNonCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below lower non critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 1 }

    cmmIpmiDeviceLNCRecovery  NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerNonCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above lower non critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 2 }

    cmmIpmiDeviceLC   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below lower critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 3 }

    cmmIpmiDeviceLCRecovery   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above lower critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 4 }

    cmmIpmiDeviceLNR   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerNonRecover
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below lower non recovery threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 5 }

    cmmIpmiDeviceLNRRecovery   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorLowerNonRecover
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above lower non recovery threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 6 }

    cmmIpmiDeviceUNC   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperNonCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below upper non critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 7 }

    cmmIpmiDeviceUNCRecovery   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperNonCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above upper non critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 8 }

    cmmIpmiDeviceUC   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below upper critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 9 }

    cmmIpmiDeviceUCRecovery   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperCritical
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above upper critical threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 10 }

    cmmIpmiDeviceUNR   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperNonRecover
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be below upper non recovery threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 11 }

    cmmIpmiDeviceUNRRecovery   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName,
        cmmIpmiDeviceSensorValue,
        cmmIpmiDeviceSensorUpperNonRecover
    }
    STATUS       current
    DESCRIPTION
    "Set when IPMI device sensor will be above upper non recovery threshold for sensor"
    ::= { cmmIpmiDeviceAlarmNotifications 12 }

    cmmIpmiDevicePresence   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName
    }
    STATUS       current
    DESCRIPTION
    "Notified when IPMI device inserted/removed"
    ::= { cmmIpmiDeviceAlarmNotifications 13 }

    cmmIpmiDeviceStatus   NOTIFICATION-TYPE
    OBJECTS      {
        cmmStackUnitIndex,
        cmmIpmiDeviceSensorName
    }
    STATUS       current
    DESCRIPTION
    "Notifies IPMI device status"
    ::= { cmmIpmiDeviceAlarmNotifications 14 }

END